Omega CNiS8DH, CNiS16 Wiring Outputs, RS-232 Output Wiring Hookup b RS-485 Output Wiring Hookup

Page 15

2.3.5 Wiring Outputs (continued)

This device may also have a programmable communication output. The RS-232 and RS-485 Output Connection are shown below.

If your meter has the communication option, the internal excitation is not available. Use external excitation for strain gauge meter.

External RS-232 connections are not available with -EI or C4EI options.

Figure 2.12

a) RS-232 Output Wiring Hookup b) RS-485 Output Wiring Hookup

dc CONTROLLED SSR USED WITH TEMPERATURE CONTROLLER WITH dc VOLTAGE SSR DRIVER OUTPUT

Vac

TEMPERATURE CONTROLLER

CONTROL

dc INPUT

LOAD

 

 

SSR

 

SIDE

4

1

SIDE

HEATER

 

 

Vac

 

 

 

 

 

3

2

 

 

0 or 5 Vdc,

 

 

 

 

 

 

TYPICALLY

FAST BLOW

FUSE

 

ac CONTROLLED SSR USED WITH TEMPERATURE CONTROLLER WITH MECHANICAL RELAY OUTPUT

Vac

TEMPERATURE CONTROLLER

CONTROL

ac INPUT

LOAD

 

 

SSR

 

SIDE

 

SIDE

HEATER

4

1

 

 

 

 

 

 

 

Vac

 

3

2

 

 

 

 

 

 

FAST BLOW

Vac

FUSE

DRIVING

 

SSR

 

ac CONTROLLED SSR USED WITH TEMPERATURE CONTROLLER WITH TRIAC OUTPUT

 

TEMPERATURE

CONTROL SIDE

ac INPUT

 

 

 

LOAD

LOAD

 

 

 

CONTROLLER

 

 

 

 

SSR

 

 

 

 

RESISTOR

 

SIDE

HEATER

 

 

 

4

1

Vac

 

 

Vac

 

 

 

 

3 2

FAST BLOW

VacFUSE

DRIVING

SSR

Figure 2.13 Typical Applications

11

Image 15
Contents CNiS8, CNiS8C CNiS8DH, CNiS8DV CNiS16, CNiS16D, CNiS32 Servicing North America Table of Contents List of Tables List of FiguresTIP Description Part IntroductionEMC Considerations Safety ConsiderationsBefore You Begin Rear Panel Connections Part SetupFront Panel Front Panel AnnunciatorsOption PowerInput OutputMain Power Connections Fuse Requirements Electrical Installation Power Connections Process Current Strain Gauge Figure below shows the wiring hookup for 4-wire bridge inputOutputs Wiring Hookup 11 Snubber Circuits Wiring HookupRS-232 Output Wiring Hookup b RS-485 Output Wiring Hookup Wiring OutputsExcitation Output Top View Location of S2 on 1/8 DIN Compact UnitJumper Connections Turning your Controller On for the First Time Part Operation Configuration ModeFlow Chart for ID and Set Points Menu Menu ConfigurationEntering Your NON-DEFAULT Full Security ID Number Entering Your NON-DEFAULT SETPOINT/ID Security ID NumberID Number Menu Setpoint Set Points MenuConfiguration Menu Enter Configuration MenuInput Type Menu Ratiometric Operation Submenu INPUT/READING Resolution SubmenuEnter Input Type Menu Input Type MenuButton Selection Submenu Reading Configuration MenuLinearization Points Submenu Enter Reading Configuration MenuDecimal Point Submenu KNOWN/UNKNOWN Loads SubmenuFilter Constant Submenu Example 1 Scaling with Known Loads On-Line Calibration Input/Reading Scale and Offset MenuInput Resolution Multiplier Conversion TableExample 2 Scaling without Known Loads Page Page Enter Alarm 1 Menu Alarm 1 MenuAlarm 1 ENABLE/DISABLE Submenu Alarm 1 ABSOLUTE/DEVIATION SubmenuAlarm 1 LATCH/UNLATCH Submenu Active Submenu Contact Closure SubmenuAlarm ENABLE/DISABLE AT Power on Alarm 1 LOW Value SubmenuAlarm 1 HI Value Submenu Enter Analog Output Menu Analog Output Retransmission MenuOUT Analog Output ENABLE/DISABLE SubmenuCURRENT/VOLTAGE Submenu ReadingFor example Enter Alarm 2 Menu Alarm 2 MenuAlarm 2 ENABLE/DISABLE Submenu Loop Break Time MenuEnter Loop Break Time Menu Loop Break ENABLE/DISABLE Submenu Setpoint Deviation ENABLE/DISABLE SubmenuLoop Break Time Value Submenu Output 1 Menu Flow Chart for Output 1 MenuEnter Output 1 Menu Self SubmenuMINIMUM/PERCENT LOW Submenu Control Type Output MAXIMUM/PERCENT High SubmenuAction Type Submenu Auto PID SubmenuAnti Integral Submenu Proportional Band Submenu Start Auto Tune PIDReset Setup Submenu Rate Setup SubmenuCycle Time Submenu Deadband Submenu Damping Factor SubmenuOutput 2 Menu Enter Output 2 MenuControl Type Submenu Be called Reverse Acting Cycle Time Submenu Ramp ENABLE/DISABLE Submenu Ramp & Soak MenuEnter Ramp and Soak Menu Soak ENABLE/DISABLE Submenu Ramp Value SubmenuSoak Value Submenu Entering or Changing Your NON-DEFAULT ID Code ID Code MenuEnter ID Code Menu Entering or Changing Your Default ID Code Full Security Level SubmenuSETPOINT/ID Security Level Submenu Communication Option Menu 13 Flow Chart for Communication Option MenuParity Submenu Enter Communication Option MenuCommunication Parameters Submenu Baud SubmenuLine Feed Submenu Stop BIT SubmenuBUS Format Submenu Modbus Protocol SubmenuData Flow Mode Submenu Communication Interface Standard SubmenuData Separation Character Submenu Peak Value Submenu Alarm Status SubmenuData Format Submenu Main Reading SubmenuTransmit Time Interval Submenu Address Setup SubmenuUnit Submenu not applicable Address Value SubmenuNormal Color Display Submenu Alarm 1 Display Color SubmenuDisplay Color Selection Menu Enter Display Color Selection MenuGreen RED Amber Alarm 2 Display Color SubmenuExample Display Colors change sequencesAmber Green Control Part SpecificationsInsulation Control Output 1SSR ExcitationGeneral Factory preset value Part Factory Preset ValuesMenu Items Factory Preset Values PID Measurement Category Part CE Approvals InformationPage Page Return REQUESTS/INQUIRIES WARRANTY/DISCLAIMERData Acquisition TemperaturePRESSURE, Strain and Force FLOW/LEVEL