Omega CNiS8C, CNiS8DH, CNiS32, CNiS16D, CNiS8DV manual Set Points Menu, Setpoint

Page 20

3.2.2 Set Points Menu

SETPOINT 1:

Press a 1) Press a, if necessary until SP1 prompt appears.

Press d 2) Display shows previous value of “Setpoint 1” with 1st digit flashing.

Press b & c 3) Press b and c to increase or decrease Setpoint 1 respectively.

Holding b & c buttons down for approximately 3 seconds will speed up the rate at which the set point value increments or decrements.

Press b & c 4) Continue to use b and c to enter your 4-digit Setpoint 1 value.

Press d 5) Display shows STRD stored message momentarily and then advance to SP2 only, if a change was made, otherwise press a to advance to SP2 Setpoint 2 Menu.

SETPOINT 2:

Press d 6) Display shows previous value of “Setpoint 2” with 1st digit flashing.

Press b & c 7) Press b and c to increase or decrease Setpoint 2 respectively.

Holding b & c buttons down for approximately 3 seconds will speed up the rate at which the setpoint value increments or decrements.

Press d 8) Display shows STRD stored message momentarily and then advances to CNFG only, if a change was made, otherwise press a to advance to CNFG Configuration Menu.

16

Image 20
Contents CNiS8, CNiS8C CNiS8DH, CNiS8DV CNiS16, CNiS16D, CNiS32 Servicing North America Table of Contents List of Figures List of TablesTIP Part Introduction DescriptionSafety Considerations EMC ConsiderationsBefore You Begin Part Setup Front PanelFront Panel Annunciators Rear Panel ConnectionsPower InputOutput OptionElectrical Installation Power Connections Main Power Connections Fuse RequirementsProcess Current Figure below shows the wiring hookup for 4-wire bridge input Strain Gauge11 Snubber Circuits Wiring Hookup Outputs Wiring HookupWiring Outputs RS-232 Output Wiring Hookup b RS-485 Output Wiring HookupJumper Connections Excitation OutputTop View Location of S2 on 1/8 DIN Compact Unit Part Operation Configuration Mode Turning your Controller On for the First TimeMenu Configuration Flow Chart for ID and Set Points MenuID Number Menu Entering Your NON-DEFAULT Full Security ID NumberEntering Your NON-DEFAULT SETPOINT/ID Security ID Number Set Points Menu SetpointInput Type Menu Configuration MenuEnter Configuration Menu INPUT/READING Resolution Submenu Enter Input Type MenuInput Type Menu Ratiometric Operation SubmenuReading Configuration Menu Button Selection SubmenuEnter Reading Configuration Menu Decimal Point SubmenuKNOWN/UNKNOWN Loads Submenu Linearization Points SubmenuFilter Constant Submenu Input/Reading Scale and Offset Menu Example 1 Scaling with Known Loads On-Line CalibrationExample 2 Scaling without Known Loads Input Resolution MultiplierConversion Table Page Page Alarm 1 Menu Enter Alarm 1 MenuAlarm 1 LATCH/UNLATCH Submenu Alarm 1 ENABLE/DISABLE SubmenuAlarm 1 ABSOLUTE/DEVIATION Submenu Contact Closure Submenu Active SubmenuAlarm 1 HI Value Submenu Alarm ENABLE/DISABLE AT Power onAlarm 1 LOW Value Submenu Analog Output Retransmission Menu Enter Analog Output MenuAnalog Output ENABLE/DISABLE Submenu CURRENT/VOLTAGE SubmenuReading OUTFor example Alarm 2 Menu Enter Alarm 2 MenuEnter Loop Break Time Menu Alarm 2 ENABLE/DISABLE SubmenuLoop Break Time Menu Loop Break Time Value Submenu Loop Break ENABLE/DISABLE SubmenuSetpoint Deviation ENABLE/DISABLE Submenu Flow Chart for Output 1 Menu Output 1 MenuMINIMUM/PERCENT LOW Submenu Enter Output 1 MenuSelf Submenu MAXIMUM/PERCENT High Submenu Control Type OutputAnti Integral Submenu Action Type SubmenuAuto PID Submenu Start Auto Tune PID Proportional Band SubmenuCycle Time Submenu Reset Setup SubmenuRate Setup Submenu Damping Factor Submenu Deadband SubmenuControl Type Submenu Output 2 MenuEnter Output 2 Menu Be called Reverse Acting Cycle Time Submenu Enter Ramp and Soak Menu Ramp ENABLE/DISABLE SubmenuRamp & Soak Menu Soak Value Submenu Soak ENABLE/DISABLE SubmenuRamp Value Submenu Enter ID Code Menu Entering or Changing Your NON-DEFAULT ID CodeID Code Menu SETPOINT/ID Security Level Submenu Entering or Changing Your Default ID CodeFull Security Level Submenu 13 Flow Chart for Communication Option Menu Communication Option MenuEnter Communication Option Menu Communication Parameters SubmenuBaud Submenu Parity SubmenuStop BIT Submenu BUS Format SubmenuModbus Protocol Submenu Line Feed SubmenuData Separation Character Submenu Data Flow Mode SubmenuCommunication Interface Standard Submenu Alarm Status Submenu Data Format SubmenuMain Reading Submenu Peak Value SubmenuAddress Setup Submenu Unit Submenu not applicableAddress Value Submenu Transmit Time Interval SubmenuAlarm 1 Display Color Submenu Display Color Selection MenuEnter Display Color Selection Menu Normal Color Display SubmenuAlarm 2 Display Color Submenu ExampleDisplay Colors change sequences Green RED AmberAmber Green Part Specifications ControlControl Output 1 SSRExcitation InsulationGeneral Part Factory Preset Values Factory preset valueMenu Items Factory Preset Values PID Part CE Approvals Information Measurement CategoryPage Page WARRANTY/DISCLAIMER Return REQUESTS/INQUIRIESTemperature PRESSURE, Strain and ForceFLOW/LEVEL Data Acquisition