Soleus Air KFHHP-22 service manual Specifications and technical parameters

Page 2

2Specifications and technical parameters

Model

 

 

 

 

 

KFHHP-22

Function

 

 

 

COOLING

 

HEATING

Rated Voltage

 

 

 

 

208-230V~

 

 

 

 

 

 

 

 

 

Total Capacity (W)

23800/22000Btu

 

27000/24200Btu

 

 

 

 

 

 

 

 

 

Rated Input (W)

2240

 

 

2280

Rated Current (A)

10.18

 

 

10.36

Air Flow Volume (m3/h) (H/M/L)**

1050/950/880

Dehumidifying Volume (l/h)

 

 

 

 

 

3

 

 

 

 

 

 

 

 

Model of Indoor Unit

 

 

 

 

KFHHP-22-ID

 

Fan Motor Speed (r/min)

1400/1300/1200

 

Output of Fan Motor (w)

 

 

 

 

 

20

 

Input of Heater (w)

 

 

 

 

 

/

 

Fan Motor Capacitor (uF)

 

 

 

 

 

3

 

Fan Motor RLA(A)

 

 

 

 

 

0.4

 

Fan Type-Piece

 

 

 

 

Cross flow fan – 1

 

Diameter-Length (in)

 

 

 

 

φ4.17 X35.04

 

Evaporator

 

 

 

 

Aluminum fin-copper tube

Indoor

Pipe Diameter (in)

 

 

 

 

 

Φ0.28

Unit

Row-Fin Gap(in)

 

 

 

 

 

2-0.055

 

Coil lengthxheightxcoil width(in)

 

 

 

 

35.5X0.083X15

 

Swing Motor Model

 

 

 

 

MP24GA

 

Output of Swing Motor (W)

 

 

 

 

 

2

 

Fuse (A)

 

 

 

 

PCB 3.15A

Transformer 0.2A

 

Sound Pressure Level dB (A)

52/50/48

 

Sound Power Level dB (A)

62/60/58

 

Dimension ( in)

 

 

 

 

46.38 X12.83X8.94

 

Dimension of Package(in)

 

 

 

 

49.8X16.42X13.11

 

Net Weight /Gross Weight(lb)

 

 

 

 

 

38.6/53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 2
Contents Introduction and features Model RemarksSpecifications and technical parameters KFHHP-22KFHHP-22-OD Components name Indoor unit Outdoor unitOverall and installation dimension Overall and installation dimension of indoor unitOverall and installation dimension of outdoor unit NutGggggKFHHP-22 Other control Temperature parametersFundamental function Communication failure Dehumidifying mode Parameters of temperatureCool mode Fan modeCurrent protection function Overcurrent protection Time-delay protection of compressorHigh exhausting gas temp. protection of compressor Defrosting processCommunication failure Testing of malfunction of temp. sensor and IPM overheatingFrequency demultiplying, limitation of current control Module protectionStatus of indicator in outdoor unit D11D17 Disassemble filter Disassemble guide louverDisassemble electrical box Disassemble front caseDisassemble electrical box cover Disassemble water tray Disassemble evaporator assyDisassemble motor Disassemble cross flow fanDisassembly procedures for outdoor unit Operating procedures /picturesDisassemble housing case Disassemble 4-way valve Disassemble motor and motor supportOperating procedures/pictures Disassemblle capillaryExploded view and components&part list Indoor unitComponents and part list of indoor unit KFHHP-22-OD Components and part list of outdoor unit PCB JGP011Troubleshooting Replace the controller Change batteryPage Poor cooling heating effect Improper setting of temperature Wrap and tight it again Malfunction display section Rectifying bridge, reactor, capacitance etc. is ok