Soleus Air KFHHP-22 service manual Components and part list of outdoor unit, PCB JGP011

Page 26

Components and part list of outdoor unit

No

Description

 

Part Code

Qty

 

KFHHP-22-OD

 

 

 

 

1

Front Grill

01473001

1

2

Housing

01433011

1

3

Small Handle

26235401

1

4

Clapboard Assy

01233039

1

5

Axial Flow Fan

10335253

1

6

Fan Motor FW60H

15013704

1

7

Motor Support Sub-Assy

01703087

1

8

Condenser Assy

01103813

1

9

Temp Sensor Support

24213005

1

10

Top Cover

01255262

1

11

Rear Grill

01475252

1

12

Reactor

43120011

1

13

Electric Box Assy

01403591

1

14

Module Support

24213008

1

15

PCB JGP011

30111018

1

16

Electric Box Cover Sub-Assy

01403629

1

17

Main PCB 2 W9W2

30039165

1

18

PCB Support￿up￿

26153031

8

19

PCB Support￿down￿

24213010

8

20

PCB Support

24213009

1

21

Main PCB 1 W9W2

30039164

1

22

Filtering Board W9W2

30039163

1

23

Temperature Sensor

3900028001

1

24

Sensor Insert

42020063

1

25

Sensor Insert

42020066

1

26

Capacitor

33010027

1

27

Terminal Board

42010255

1

28

Filter

43130008

1

29

Wire Clamp

71010102

1

30

Isolation Washer

70410523

1

31

Wire Clamp

71010003

1

32

Cable-Cross Loop

76514004

5

33

Radiator

49013011

1

34

Capillary Sub-Assy

03103391

1

35

Cut-off Valve

07130209

1

36

4-way Valve

43000411

1

37

4-way Valve Fittings

 

 

1

4300040022

38

Gas Valve Sub-Assy

07103030

1

39

Rear Side Plate Sub-Assy

01302005

1

40

Compressor

00103501

1

41

Underpan Assy

01203560

1

42

Front Side Plate

01302007

1

43

Choke Plug

06813401

1

 

 

 

 

 

-26-

Image 26
Contents Introduction and features Model RemarksSpecifications and technical parameters KFHHP-22KFHHP-22-OD Components name Indoor unit Outdoor unitOverall and installation dimension Overall and installation dimension of indoor unitOverall and installation dimension of outdoor unit NutGggggKFHHP-22 Other control Temperature parametersFundamental function Communication failure Dehumidifying mode Parameters of temperatureCool mode Fan modeCurrent protection function Overcurrent protection Time-delay protection of compressorHigh exhausting gas temp. protection of compressor Defrosting processCommunication failure Testing of malfunction of temp. sensor and IPM overheatingFrequency demultiplying, limitation of current control Module protectionStatus of indicator in outdoor unit D11D17 Disassemble filter Disassemble guide louverDisassemble electrical box Disassemble front caseDisassemble electrical box cover Disassemble water tray Disassemble evaporator assyDisassemble motor Disassemble cross flow fanDisassembly procedures for outdoor unit Operating procedures /picturesDisassemble housing case Disassemble 4-way valve Disassemble motor and motor supportOperating procedures/pictures Disassemblle capillary Exploded view and components&part list Indoor unitComponents and part list of indoor unit KFHHP-22-OD Components and part list of outdoor unit PCB JGP011Troubleshooting Replace the controller Change batteryPage Poor cooling heating effect Improper setting of temperature Wrap and tight it again Malfunction display section Rectifying bridge, reactor, capacitance etc. is ok