Poor cooling (heating) effect
Improper setting of temperature | Adjust the set temperature |
|
| |
Whether cooling (heating) load | Check the estimated load of cooling (heating) | |||
is proper |
|
|
|
|
|
|
| Vacuumize | after leakage detection |
| Leakage or shortage of refrigerant | and leakage repair. Charge refrigerant | ||
|
|
| according to specification. | |
| Leakage occurs between high and | Replace the compressor | ||
| low pressure inside compressor |
|
| |
Malfunction of | Malfunction of | Replace the | ||
refrigerant flow | ||||
| Partial blockage of capillary | Replace the capillary | ||
|
|
| Use the method of observing condensation | |
| Blockage of cooling system | on the evaporator and pressure value of | ||
| high pressure | manometer to see whether |
the system is blocked and carry out corresponding handling on the system
Poor thermal insulation of connecting | Ensure that both thick pipe and thin pipe are insulated | |
well. The exposed part of the connector and copper pipe | ||
pipe of indoor and outdoor unit | ||
must be insulated as well. | ||
|
Air circulation is insufficient
Heat exchanger of outdoor unit is blocked
Air filters are blocked
Fan speed is set too slow
Fan speed turns low
Improper installation location for outdoor unit
Clean the dust accumulated on the surface of the heat exchanger
Clean the filter
Set the fan speed to high or medium speed
Damage of | Replace | the |
capacitor | capacitor |
|
damaged |
|
|
Damage of | Replace the motor | |
motor |
|
|
Outdoor unit should be installed in a place with well ventilation
Outdoor temperature is too high
Indoor sealability is inadequate; too many people go in and out frequently; there is heating unit in the room.
Flashing or awning can be installed appropriately. If the max. cooling capacity cannot be satisfied, replacement of the air conditioner is recommended.
Maintain a certain degree of indoor sealability. Try not to use appliance with high amount of heat.