3.10 Electrical connections

Warning: For safety reasons, disconnect the power supply cord to the heater before any service or testing is performed.

Warning: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code NFPA 70. In Canada, all electrical wiring to the heater should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the metal parts of the heater.

The 2400 E requires an electrical power supply from a 120VAC / 60Hz circuit (with a dedicated outlet) and must be properly grounded.

A means for switching of f the 120VAC power supply must be provided.

The heater is wired as shown in the wiring diagram (chapter 7, Fig. 44).

3.12 Recirculation application

Since recirculation through the heater is not permissible, the following drawing is provided to outline a proper recirculation application using the Aquastar water heater with an Ariston minitank water heater. This schematic is for illustration only and must not be used for actual installation without appropriate engineering and technical advice from a properly licensed professional in the locality where the installation is made.

2400 E

Ariston Minitank

Fig. 27 Recirculation application

1Full port isolation valve

2Circulator

3Check valve

4PRV

5Expansion tank

The use of a small electric mini-tank water heater (4-6 gallon size) should be used for this application and designed so the pump will circulate the water through the mini-tank and the building's hot water return loop only. Timed or thermostatically controlled operation of the pump is commonly done. The 2400 E must be supplied with cold water only and plumbed in line before the mini-tank water heater. Contact Bosch Water Heating if further information is needed.

6 720 608 263

23

Image 23
Contents What to do if you smell gas NG Natural Gas LP Liquefied Petroleum LP GasIntended for variable flow applications Index For your safetyIndex FCC Appliance details Features2400 E Specifications Technical data Unpacking the 2400 E heater Venting General rules to follow for safe operationDimensions Dimensions and Minimum installation clearancesMounting installation Installation instructionsProper location for installing your heater Heater placement and clearancesTwin pipe method Combustion air requirementsSingle pipe method Installation instructions Minimum exhaust vent size and length Vent material and specificationsVenting Vent lengthsCombustion air inlet connection Vent Safety SystemVent connections Exhaust vent connection Room sealed installation Twin pipe External condensate drain installation not suppliedInterior masonry chimneys Vertical terminationsHorizontal runs Vent terminationsHorizontal terminations Exterior masonry chimneysInstallation instructions Description Minimum distance 720 608 Gas piping & connections For Natural GAS Operating Pressure Test Connecting ManometerMeasuring gas pressure Static Pressure TestHotcold Water connectionsRecirculation application Electrical connectionsOperation instructions For your safety, read before oper- ating your water heaterPower Operation instructionsOperation instructions Off Temperature selectionFlow/temperature chart Operation instructions Setting the water temperatureProgram button Use of optional remote control accessoryReset button OperationWinterizing for seasonal use Maintenance and serviceAnnual maintenance Once Gas Pressure is adequate Adjusting CO2Descaling using a pump Mineral scale build-upAdjusting CO2 cover removed Measuring CO2 Cover InstalledFinal Readings Returning to ServiceDiagnostic menu Control board diagnosticsWater is not hot enough TroubleshootingTroubleshooting Water is too hotNoisy burner/heater during operation Hot water temperature fluctuates at tapLow water flow/pressure Lack of gas pressure. Inadequate gas pressure will Display Cause Solution Error code diagnosticsMeet desired temperature Check red wire connections at hot water Troubleshooting Display Cause SolutionNo flame ionization detected with water Heat exchanger Flame ionization rod or control unit may be Electrical diagram Electrical diagramFunctional scheme Functional schemeInterior components Interior components diagram and parts listInterior components diagram and parts list Components Diagram Components diagramDescription Reference Parts listComponents Protecting the environmentProtecting the environment PackingTwelve Year Limited Warranty BBT North America

2400E NG, 2400E LP specifications

Bosch Appliances has long been synonymous with quality and innovation in the kitchen appliance sector. Among their impressive lineup, the Bosch 2400E LP (Liquid Propane) and 2400E NG (Natural Gas) models stand out as prime examples of the brand’s commitment to performance and functionality.

Both the 2400E LP and 2400E NG are designed with user convenience and culinary excellence in mind. One of the most notable features of these appliances is their exceptional heat distribution, which ensures that food cooks evenly. This is particularly beneficial for grilling, where inconsistent heat can lead to unevenly cooked meals. The burners are crafted to provide high-efficiency performance while consuming less fuel, making them an economical choice for both home cooks and culinary enthusiasts.

Each model boasts a sleek, modern design that can seamlessly integrate into various kitchen styles. The stainless steel construction not only enhances aesthetics but also increases durability, ensuring the appliance can withstand the rigors of daily use while maintaining its appearance. The 2400E series also features a compact size, making it suitable for kitchens of all dimensions, including those with space constraints.

In addition to design and performance, safety features are a priority for Bosch. The 2400E models come equipped with sturdy flame control knobs, allowing users to adjust heat settings with precision, reducing the risk of accidental flare-ups. Moreover, the integrated ignition system is designed for reliability, ensuring that starting the unit is hassle-free.

Versatility is another hallmark of the Bosch 2400E LP and NG models. These appliances are compatible with a range of cooking accessories, from griddles to rotisserie attachments, providing multiple cooking methods to satisfy diverse culinary endeavors. The grease management system is another highlight, simplifying cleanup and maintenance after cooking sessions.

Another innovative technology in the Bosch 2400E series is the Smart Grilling feature, which includes temperature sensors that provide real-time feedback. This allows users to monitor cooking progress effortlessly, enhancing the overall cooking experience. The models also include a robust warranty, ensuring peace of mind for consumers.

In conclusion, Bosch Appliances’ 2400E LP and NG models represent a fine balance of innovation, safety, and style. With their powerful cooking capabilities, thoughtful design features, and user-friendly technologies, they stand as excellent choices for anyone looking to elevate their cooking experience.