| Troubleshooting | |
|
|
|
|
Display | Cause | Solution |
|
|
|
|
|
C1 | Fan rotation too low on startup. | 1. Disconnect power supply cord. Check wire |
|
| (part# 8707204039) | connections on back side of fan and the two large |
|
|
| wire connectors on the control unit. Removal of |
|
|
| lower access panel on control unit is necessary to |
|
|
| access connectors. |
|
|
| 2. Verify that supply voltage is 120VAC and is |
|
|
| properly grounded. |
|
|
| 3. Verify that venting meets specifications outlined |
|
|
| in chapter 3.6. Long vent lengths, venting with more |
|
|
| than three elbows, blocked vent or combination |
|
|
| venting may cause this failure. Verify backdraft |
|
|
| flapper inside flue gas collector is not stuck shut. |
|
|
| 4. Check gas pressure. See chapter 3.8. Low gas |
|
|
| pressure may cause the fan to change its speed to |
|
|
| meet desired temperature. |
|
|
| 5. Possible defective control unit. Call Bosch Water |
|
|
| Heating for further instructions. |
|
|
|
|
|
C6 | Fan rotation too low in operation | 1. Disconnect power supply cord. Check wire |
|
| (part# 8707204039) | connections on back side of fan and the two large |
|
|
| wire connectors on the control unit. Removal of |
|
|
| lower access panel on control unit is necessary to |
|
|
| access connectors. |
|
|
| 2. Check supply voltage is 120VAC and is properly |
|
|
| grounded. |
|
|
| 3. Verify that venting meets specifications outlined |
|
|
| in chapter 3.6. Long vent lengths, venting with more |
|
|
| than three elbows, blocked vent or combination |
|
|
| venting may cause this failure. Verify backdraft |
|
|
| flapper inside flue gas collector is not stuck shut. |
|
|
| 4. Ensure intake and exhaust terminations maintain |
|
|
| the required clearances stated in the manual ( Fig. |
|
|
| 17 and Table 6 on page 17). Cross |
|
|
| contamination between intake and exhaust may |
|
|
| cause the fan to alter its rotational speed. |
|
|
| 5. Check gas pressure. See chapter 3.8*. Low gas |
|
|
| pressure may cause the fan to change its speed to |
|
|
| meet desired temperature. |
|
|
| 6. Possible defective control unit. Call Bosch Water |
|
|
|
|
|
C7 | No rotational speed sensor from fan. | 1. Disconnect power supply cord. Check wire |
|
| (part# 8707204039) | connections on back side of fan and the two large |
|
|
| wire connectors on the control unit. Removal of |
|
|
| lower access panel on control unit is necessary to |
|
|
| access connectors. |
|
|
| 2. Check supply voltage is 120VAC and is properly |
|
|
| grounded. |
|
|
| 3. Possible defective component in fan. Call Bosch |
|
|
| Water Heating for further instructions. |
|
|
|
|
|
CA | Water flow signal over specified maximum | 1. Disconnect power supply cord and check wire |
|
| value. | connections on water valve and the two connectors |
|
| (part# 8708505016) | on the control board. |
|
|
| 2. Excessive water pressure and flow. Ensure water |
|
|
| pressure is less than 150psi and flow rate is less |
|
|
| than 10 gallons per minute. |
|
|
|
|
|
Table 12
* By installer or service technician only.
6 720 608 263 | 37 |