Table PD-11 — Gross Heating Capacities (MBh)

Performance

Data(System)

Table PD-11 — Gross Heating Capacities (MBh)

TWA155B Heat Pump with TWE155B Air Handler At 5000 CFM (I-P)

Outdoor

Heating Capacity (BTUH/1000) At

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°F)

60

70

75

80

60

70

75

80

-18

68.8

60.9

58.1

55.9

11.9

12.3

12.5

12.8

-13

71.2

64.2

61.7

59.9

11.9

12.3

12.6

12.9

-8

74.3

68.2

66.2

64.7

11.9

12.4

12.7

13.2

-3

78.2

73.2

71.6

70.5

11.9

12.5

12.9

13.4

2

83.0

79.0

77.8

77.0

11.9

12.7

13.1

13.7

7

88.7

85.7

84.8

84.4

12.0

12.9

13.4

14.0

12

95.5

93.2

92.6

92.4

12.2

13.1

13.7

14.3

17

103.3

101.6

101.2

101.1

12.3

13.4

14.0

14.7

22

112.1

110.9

110.6

110.6

12.5

13.6

14.3

15.1

27

121.8

120.9

120.7

120.6

12.8

14.0

14.7

15.5

32

132.5

131.7

131.4

131.2

13.1

14.3

15.0

15.8

37

143.4

142.6

142.2

141.8

13.3

14.7

15.4

16.2

42

154.8

153.9

153.3

152.7

13.6

15.0

15.8

16.6

47

167.0

165.7

165.0

164.1

14.0

15.4

16.1

17.0

52

179.9

178.2

177.2

176.1

14.3

15.7

16.5

17.3

57

193.3

191.2

189.9

188.6

14.6

16.1

16.9

17.7

62

207.2

204.5

203.0

201.4

15.0

16.4

17.2

18.0

67

221.3

218.2

216.4

214.5

15.3

16.8

17.6

18.4

72

235.8

232.2

230.3

228.2

15.7

17.2

18.0

18.8

Table PD-11 — Gross Heating Capacities (kW)

TWA155B Heat Pump with TWE155B Air Handler At 8494 m3/h (SI)

Outdoor

Heating Capacity (kW) At

 

 

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°C)

15.6

21.1

23.9

26.7

 

15.6

21.1

23.9

26.7

-27.8

20.1

17.8

17.0

16.4

 

5.5

6.0

6.2

6.5

-25.0

20.9

18.8

18.1

17.5

 

5.6

6.1

6.3

6.6

-22.2

21.8

20.0

19.4

19.0

 

5.7

6.2

6.5

6.7

-19.4

22.9

21.4

21.0

20.6

 

5.8

6.3

6.6

6.9

-16.7

24.3

23.1

22.8

22.6

 

5.9

6.5

6.7

7.0

-13.9

26.0

25.1

24.8

24.7

 

6.0

6.6

6.9

7.2

-11.1

28.0

27.3

27.1

27.0

 

6.2

6.7

7.0

7.4

-8.3

30.2

29.8

29.6

29.6

 

6.3

6.9

7.2

7.5

-5.6

32.8

32.5

32.4

32.4

 

6.5

7.0

7.4

7.7

-2.8

35.7

35.4

35.3

35.3

 

6.6

7.2

7.5

7.9

0.0

38.8

38.6

38.5

38.4

 

6.8

7.4

7.7

8.1

2.8

42.0

41.7

41.6

41.5

 

6.9

7.6

7.9

8.3

5.6

45.3

45.0

44.9

44.7

 

7.1

7.8

8.1

8.5

8.3

48.9

48.5

48.3

48.1

 

7.3

8.0

8.4

8.8

11.1

52.7

52.2

51.9

51.6

 

7.5

8.2

8.6

9.0

13.9

56.6

56.0

55.6

55.2

 

7.7

8.4

8.8

9.2

16.7

60.7

59.9

59.4

59.0

 

7.9

8.7

9.1

9.5

19.4

64.8

63.9

63.4

62.8

 

8.1

8.9

9.3

9.8

22.2

69.0

68.0

67.4

66.8

 

8.4

9.2

9.6

10.0

Correction Factors - Other Airflows“(Table Value

 

Airflow = 5000 cfm (8495 m3/h)

 

 

Correction Factor = Value at new airflow)

 

 

Heating Capacity (High Temp.) = 166,000 (48.60)

 

Airflow

4500 cfm

5500 cfm

 

 

Heating Capacity (Low Temp.) = 101,000 (29.57)

 

 

7645 m3/h

9344 m3/h

 

 

Compressor Power (High Temp) = 11.67 kW

 

 

 

 

 

 

Compressor Power (Low Temp) = 9.66 kW

 

Heating Capacity

x 0.99

x1.01

 

 

Coeff. Of Perf. (High Temp) = 3.2

 

 

Compressor kW

x1.02

x0.98

 

 

Coeff. Of Perf. (Low Temp) = 2.2

 

 

 

 

 

 

 

Outdoor Fan Power = 1100 watts

 

 

Values at ARI Rating Conditions of:

 

 

Indoor Fan Power = 2570 watts

 

 

70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)

 

 

 

 

 

 

70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)

 

Note:

 

 

 

 

 

 

 

 

 

1.Rated with 25 feet of 1-3/8"" suction and 1/2"" liquid line."

22

SSP-PRC002-EN

Page 22
Image 22
Trane TWA200B Performance, DataSystem, Table PD-11- Gross Heating Capacities MBh, Table PD-11- Gross Heating Capacities kW