Trane TWE050A, TWA075A, TWE200B, TWA200B manual Electrical Data, Table ED-2- UnitWiring - Air Handler

Models: TWA200B TWA075A TWE200B TWE050A

1 56
Download 56 pages 34.19 Kb
Page 31
Image 31
Electrical

Electrical

Data

Table ED-1— Electrical Characteristics — Motors — Air Handler

 

 

 

Standard Fan Motor

 

 

 

Oversized Fan Motor

 

Unit

 

 

 

Amps

 

 

 

 

Amps

 

Model No.

Volts

Phase

 

FLA

LRA

 

Phase

 

FLA

LRA

TWE050

380/415

3

1.4

8.2

3

1.8

21.6

TWE075

380/415

3

3.2

19.7

3

4.0

25.5

TWE100

380/415

3

3.6

25.5

3

5.3

37.5

TWE155

380/415

3

4.6

37.5

3

6.9

39.2

TWE200

380/415

3

7.6

39.2

3

9.0

65.1

Table ED-2 — UnitWiring — Air Handler

 

 

Minimum

Maximum Fuse

Unit

Unit Operating

Circuit

Size or Maximum

Model No.

Voltage Range

Ampacity

Circuit Breaker

 

 

 

 

TWE050

380/415

2

15

TWE075

380/415

4

15

TWE100

380/415

5

15

TWE155

380/415

6

15

TWE200

380/415

10

15

Table ED-3— Electrical Characteristics — Motors — 50 Cycle — Heat Pumps

 

 

Compressor Motor

 

 

 

Condenser Fan Motor

 

 

 

 

 

Amps

 

 

 

 

Amps

Unit

 

 

 

RLA

LRA

 

 

 

 

FLA

LRA

Model No.

No.

Volts

Phase

(Ea.)

(Ea.)

 

No.

Volts

Phase

(Ea.)

(Ea.)

TWA075AD

1

380/415

3

8.8

90.0

1

380/415

1

1.6

3.7

TWA100AD

1

380/415

3

15.8

124.0

1

380/415

1

2.7

7.0

TWA155BD

2

380/415

3

11.2

94.8

2

380/415

1

1.6

3.7

TWA200BD

2

380/415

3

15.8

124 .0

2

380/415

1

2.7

7.0

Table ED-4 — UnitWiring — Heat Pumps

 

 

Minimum

Maximum Fuse

Unit

Unit Operating

Circuit

Size or Maximum

Model No.

Voltage Range

Ampacity

Circuit Breaker

 

 

 

 

TWA075

380/415

12.6

50

TWA100

380/415

22.5

35

TWA155

380/415

28.4

35

TWA200

380/415

41.0

50