Trane TWA200B, TWA075A, TWE200B, TWE050A manual Table GD-2General Data - Heat Pumps

Models: TWA200B TWA075A TWE200B TWE050A

1 56
Download 56 pages 34.19 Kb
Page 10
Image 10
Table GD-2 General Data — Heat Pumps

General

 

Data

(Heat Pumps)

Table GD-2 General Data — Heat Pumps

 

TWA155B

TWA200B

Cooling Performance1

 

 

Gross Cooling Capacity, Btu (kW)

 

 

Matched Air Handler, Btu (kW)

167,000 (48.9)

218,000 (63.83)

Condensing Unit Only2, Btu (kW)

167,000 (48.9)

218,000 (63.83)

ARI Net Cooling Capacity3

162,000 (47.43)

211,000 (61.78)

System Power kW

15.67

21.51

Condensing Unit Power kW

13.91

19.1

Heating Performance

 

 

ARI Heating with Matched Air Handler

 

 

HighTemperature Capacity, Btu (kW)

166,000 (48.6)

214,000 (62.66)

LowTemperature Capacity, Btu (kW)

101,000 (29.57)

139,000 (40.70)

Compressor

 

 

Number

2

2

Type

3D®Scroll

3D®Scroll

No. Motors

2

2

Motor HP

6.25 (4.7)

8.33 (6.21)

Motor RPM, (kW)

2875

2875

ARI Sound Rating (Bels)4

8.8

8.8

System Data5

 

 

No. Refrigerant Circuits

2

2

Suction Line, in. (mm) OD

1.375 (34.9)

1.375 (34.9)

Liquid Line, in. (mm) OD

0.500 (12.7)

0.500 (12.7)

Outdoor Coil —Type

Plate Fin

Plate Fin

Tube Size, in. (mm) OD

0.375 (9.5)

0.375 (9.5)

Face Area, sq. ft (m2)

38.4 (3.57)

48 (4.46)

Rows

2

2

Fins Per Inch

18

18

Outdoor FanType

Propeller

Propeller

No. Used

2

2

Diameter, in. (mm)

26.00 (660.4)

28.00 (711)

DriveType

Direct

Direct

No. Speeds

1

1

CFM6, (m3/h)

9800 (16650.2)

13400 (22766.60)

No. Motors

2

2

Motor HP (kW)

0.33 (.25)

0.75 (.56)

Motor RPM

925

925

R-22 Refrigerant Charge, lb7 (kg)

36.0 (16.33)

48.5 (22.0)

Notes:

1.Cooling Performance is rated at 95°F (35°C) ambient, 80°F (26.7°C) entering dry bulb, 67°F (19.4°C) entering wet bulb and nominal cfm listed. ARI rating cfm is 350 cfm/ton for this product. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Rated accordance with ARI Standard 340/360-00.

2.Condensing Unit Only Gross Cooling Capacity rated at 45°F (7.6°C) saturated suction temperature and at 95°F (35°C) ambient.

3.ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft (7.6 m) of 1.375, 0.500 OD interconnect- ing tubing. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. Integrated Part Load Value is based on ARI Standard 340/360-00. Units are rated at 80°F (26.7°C) ambient, 80°F (26.7°C) entering dry bulb, and 67°F (19.4°C) entering wet bulb at ARI rated cfm.

4.ARI Sound Rating is rated in accordance with ARI Standard 270 or 370.

5.System Data based on maximum linear length 80 ft (26.7 m)Maximum lift: suction 60 ft (18.3 m) liquid 60 ft (18.3 m) For greater lengths, refer to refrigerant piping applications manual.

6.Outdoor Fan cfm is rated with standard air-dry coil outdoor.

7.Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft (7.6 m) of interconnecting refrigerant lines.