Carrier R-410A manual Medium-Static Drive Data, 60 Hz SI, High-Static Drive Data, 60 Hz SI

Page 29

Table 9E — Medium-Static Drive Data, 60 Hz — SI

UNIT

40RUA*25

40RUA*28

40RUA*30

40RUS*25

40RUS*28

40RUS830

 

MOTOR DRIVE

 

 

 

Motor Pulley Pitch Diameter (mm)

109.2-

109.2-

109.2-

134.6

134.6

134.6

 

Pulley Factory Setting

3.0

3.0

3.0

Full Turns Open

 

 

 

FAN DRIVE

 

 

 

Pulley Pitch Dia (mm)

239

239

239

Pulley Bore (mm)

36.5

49.2

49.2

Belt No. — Section

1—B

2—B

2—B

Belt Pitch (mm)

1062

(2) 986

(2) 986

(2) 1011

(2) 1011

 

 

FAN SPEEDS (r/s)

 

 

 

Factory Setting

14.7

14.7

14.7

Range

13.3-16.4

13.3-16.4

13.3-16.4

Max Allowable Speed (r/s)

20.0

18.3

18.3

Change per 1/2 Turn of

0.255

0.255

0.255

Moveable Motor Pulley

Flange

 

 

 

MAX FULL TURNS FROM

6

6

6

CLOSED POSITION

 

 

 

SHAFTS CENTER DISTANCE (mm)

232-279

169-240

169-240

Four belts shipped with unit. Use correct set of 2 belts sized according to the pully setting.

Table 9F — High-Static Drive Data, 60 Hz — SI

UNIT

40RUA*25

40RUA*28

40RUA*30

40RUS*25

40RUS*28

40RUS*30

 

MOTOR DRIVE

 

 

 

Motor Pulley Pitch Diameter (mm)

109.2-

109.2-

109.2-

134.6

134.6

134.6

 

Pulley Factory Setting

3.0

3.0

3.0

Full Turns Open

 

 

 

FAN DRIVE

 

 

 

Pulley Pitch Dia (mm)

188

203

203

Pulley Bore (mm)

36.5

49.2

49.2

Belt No. — Section

2—B

2—B

2—B

Belt Pitch (mm)

935

935

960

FAN SPEEDS (r/s)

 

 

 

Factory Setting

18.6

17.1

17.1

Range

16.9-

14.6-

14.6-

20.0

17.9

17.9

 

Max Allowable Speed (r/s)

20.0

18.3

18.3

Change per 1/2 Turn of

0.323

0.278

0.278

Moveable Motor Pulley

Flange

 

 

 

MAX FULL TURNS FROM

6

6

6

CLOSED POSITION

 

 

 

SHAFTS CENTER DISTANCE (mm)

207-255

169-240

169-240

It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s.

29

Image 29
Contents Installation, Start-Up Service Instructions PRE-INSTALLATION Unit Unit Weight Dimensions SizeDimensions Sizes 28 40RUA Physical Data, English Cooling Units 40RUA Physical Data, SI Cooling Units Unit 40RUS 40RUS Physical Data, English Chilled Water UnitsChilled Water Coil Steam Coil ‡40RUS Physical Data, SI Chilled Water Units U a a 2 5 a 6 0 a 0 a Overhead Suspension Accessory Unit Size Unit Sizes 28 Refrigerant and Chilled Water Piping Access Holes Face-Split Coil Suction and Liquid Line Piping Typical Fitting Requirements Factory-Installed Nozzle and Distributor DataUpper 8 Long Radius Elbow 8 Nipple, 19 1/ 4 L Fitting RequirementTypical 40RUS Chilled Water Piping Condensate Drains Fire Hazard Electrical Data, Alternate Motors Electrical Data, Standard MotorsUnit Wiring Unit Voltage Maximum Holding Fan Contactor Coil DataManufacturer Lubricant Lubricant DataFan Shaft Bearing Fan Pulley Alignment Align as follows Filter Removal/Replacement Fan Motor Data, Alternate Motor English Fan Motor Data, Standard Motor EnglishFan Motor Data, Alternate Motor SI Fan Motor Data, Standard Motor SIMedium-Static Drive Data, 60 Hz English Standard Drive Data, 60 Hz EnglishMotor Drive FAN DriveStandard Drive Data, 60 Hz SI High-Static Drive Data, 60 Hz EnglishHigh-Static Drive Data, 60 Hz SI Medium-Static Drive Data, 60 Hz SIAirflow External Static Pressure kPa 577 1042 646 716 785 100 150 200 250 300 2830 Unit Airflow Pressure Drop FACTORY-SUPPLIED Pressure Drop EnglishPreliminary Information Comp A1 Comp B1 Check Voltage Imbalance