Carrier R-410A 40RUS Physical Data, English Chilled Water Units, Unit 40RUS, Chilled Water Coil

Page 7

Table 1C — 40RUS Physical Data, English — Chilled Water Units

UNIT 40RUS*

25

 

28

 

30

NOMINAL CAPACITY (Tons)

20

 

25

 

30

OPERATING WEIGHT (lb)

 

 

 

 

 

Base Unit

683

 

1035

 

1042

Plenum

225

 

325

 

325

FANS

 

 

 

 

 

Qty...Diam. (in.)

2...15

 

2...18

 

2...18

Nominal Airflow (cfm)

8,000

 

10,000

 

12,000

Airflow Range (cfm)

6,000 – 10,000

 

7,500 – 12,500

 

9,000 – 15,000

Nominal Motor Hp (Standard Motor)

 

 

 

 

 

208/230-3-60 and 460-3-60

5.0

 

7.5

 

10.0

575-3-60

5.0

 

7.5

 

10.0

Motor Speed (rpm)

 

 

 

 

 

208/230-3-60 and 460-3-60

1745

 

1745

 

1745

575-3-60

1745

 

1755

 

1755

CHILLED WATER COIL

Enhanced Copper Tubes, Aluminum Sine-Wave Fins

Max Working Pressure (psig)

 

435

 

 

Face Area (sq ft) – Upper

11.0

 

 

15.5

 

12.4

 

Face Area (sq ft) – Lower

8.3

 

12.4

 

12.4

Rows...Fins/in.

 

3...15

 

 

PIPING CONNECTIONS,

 

 

 

 

 

Quantity...Size (in.)

 

 

 

 

 

Chilled Water — In

2...13/8 ODM

 

2...21/8 ODM

 

2...21/8 ODM

Chilled Water — Out

2...13/8 ODM

 

2...21/8 ODM

 

2...21/8 ODM

Steam Coil, In (MPT)

 

1...21/2

 

 

Steam Coil, Out (MPT)

 

1...11/2

 

 

Hot Water Coil, In (MPT)

 

1...2

 

 

Hot Water Coil, Out (MPT)

 

1...2

 

 

Condensate (PVC)

 

 

1...11/4 ODM/1 IDF

 

FILTERS

Throwaway — Factory Supplied

Quantity...Size (in.)

4...16 x 20 x 2

 

4...20 x 24 x 2

 

4...16 x 24 x 2

 

4...20 x 25 x 2

 

 

Access Location

 

 

Either Side

 

STEAM COIL

 

 

 

 

 

Max Working Pressure (psig at 260°F)

 

20

 

 

Total Face Area (sq ft)

13.33

 

 

15.0

 

15.0

 

Rows...Fins/in.

1...10

 

1...10

 

1...10

HOT WATER COIL

 

 

 

 

 

Max Working Pressure (psig)

 

150

 

 

Total Face Area (sq ft)

13.33

 

 

15.0

 

15.0

 

Rows...Fins/in.

2...8.5

 

2...12.5

 

2...12.5

Water Volume

 

 

 

 

 

(gal)

13.9

 

 

 

 

14.3

 

(ft3)

1.1

 

1.90

 

LEGEND

Field installed accessory only.

7

Image 7
Contents Installation, Start-Up Service Instructions PRE-INSTALLATION Unit Unit Weight Dimensions SizeDimensions Sizes 28 40RUA Physical Data, English Cooling Units 40RUA Physical Data, SI Cooling Units Steam Coil ‡ 40RUS Physical Data, English Chilled Water UnitsUnit 40RUS Chilled Water Coil40RUS Physical Data, SI Chilled Water Units U a a 2 5 a 6 0 a 0 a Overhead Suspension Accessory Unit Size Unit Sizes 28 Refrigerant and Chilled Water Piping Access Holes Face-Split Coil Suction and Liquid Line Piping Typical Fitting Requirements Factory-Installed Nozzle and Distributor DataUpper 8 Long Radius Elbow 8 Nipple, 19 1/ 4 L Fitting RequirementTypical 40RUS Chilled Water Piping Condensate Drains Fire Hazard Electrical Data, Alternate Motors Electrical Data, Standard MotorsUnit Wiring Unit Voltage Maximum Holding Fan Contactor Coil DataManufacturer Lubricant Lubricant DataFan Shaft Bearing Fan Pulley Alignment Align as follows Filter Removal/Replacement Fan Motor Data, Alternate Motor English Fan Motor Data, Standard Motor EnglishFan Motor Data, Alternate Motor SI Fan Motor Data, Standard Motor SIFAN Drive Standard Drive Data, 60 Hz EnglishMedium-Static Drive Data, 60 Hz English Motor DriveStandard Drive Data, 60 Hz SI High-Static Drive Data, 60 Hz EnglishHigh-Static Drive Data, 60 Hz SI Medium-Static Drive Data, 60 Hz SIAirflow External Static Pressure kPa 577 1042 646 716 785 100 150 200 250 300 2830 Unit Airflow Pressure Drop FACTORY-SUPPLIED Pressure Drop EnglishPreliminary Information Comp A1 Comp B1 Check Voltage Imbalance