Operation

Operation

Refer to the gun operation manual (supplied) for Setup, Shutdown, and Daily Care proce- dures.

INSTRUCTIONS

Low Voltage Adjustment (Smart Guns Only)

The ES HI/LO switch enables you to switch between full voltage and a lower voltage output. The lower voltage is factory set, but can be adjusted.

1.Set the ES HI/LO switch to LO.

2.Remove the LO VOLTAGE adjustment plug (53). Set the desired voltage, using a small screwdriver to slide switches 1 and 2 ON or OFF, according to Table 3 . Also see FIG. 5.

OFF

ON

2 1

0 KV 100%

μα

53

ti1529a

Fig. 5. Low Voltage Adjustment Switches

Table 3: Low Voltage Adjustment

 

 

60 kV Guns

 

85 kV Guns

 

 

 

 

 

 

 

 

 

1

 

2

kV

1

 

2

kV

 

 

 

 

 

 

 

 

 

 

ON

 

ON

50

ON

 

ON

70

 

 

 

 

 

 

 

 

 

Factory

ON

 

OFF

40

ON

 

OFF

60

 

 

 

 

 

 

 

 

OFF

 

ON

35

OFF

 

ON

50

Setting

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

30

OFF

 

OFF

40

 

 

 

 

 

 

 

 

 

309292L

15

Image 15
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Symbols Fire, Explosion, and Electric Shock HazardToxic Fluid Hazard Pressurized Equipment Hazard Equipment Misuse HazardIntroduction How the Electrostatic Air Spray Gun WorksGun Overview Flammable or Toxic Vapor Hazard InstallationInstall the System Ventilate the Spray BoothTypical Installation Key Supply Hose Connect the Air LineConnect the Exhaust Tube Electric Shock HazardOrifice Size Connect the Fluid LineFilter the Fluid Select a Fluid Nozzle and Air Cap244919 Conversion Kit HC Conversion KitGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityLow Voltage Adjustment Smart Guns Only OperationKV Guns Flush the Spray Gun MaintenanceHang the gun from its hook, with the nozzle pointing down Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceSpray Pattern Troubleshooting TroubleshootingGun Operation Troubleshooting Electrical Troubleshooting See Test Gun Resistance onSee Check Fluid Resistivity on Repair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementFluid Tube Removal Replacement PRO Xs4 Guns Only Turbine Alternator Removal and ReplacementFan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairES ON/OFF Valve Repair Atomizing Air Restrictor Valve Removal and ReplacementParts Ref. No Alternator Ref. No Fan Adjustment Valve Ref. No Packing Rod Ref. No ES ON/OFF ValveFluid Tube Model Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Accessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataTechnical Data 309292L Graco Standard Warranty Graco InformationToll Free