Installation
ES ON/OFF valve: I is ON, 0 is OFF
A
|
|
| M |
D | C* | C | O B* |
*E | H |
|
|
G | F | J* | L |
| |||
|
|
| |
|
|
| V |
|
|
| G |
|
|
| *R |
|
|
| P |
|
|
| K |
|
|
| U* |
|
|
| Q* |
|
|
| T |
|
| Hazardous Area |
I ES O
S
W
N
The air supply to the gun must be electri- cally interlocked with the ventilators to pre- vent the power supply from operating without ventilating fans on.
ti1498a
Fig. 2. Typical Installation
Key |
|
A | Main Air Supply Line |
B* | Ventilation Fan Interlock Solenoid Valve |
C* | Main Air Supply Shutoff Valve |
D | Pump Air Line Filter/Water Separator |
E* | Pump Air Supply Shutoff Valve |
FAir Line Lubricator
GAir Pressure Regulator
HPump
J* Pump Ground Wire
KFluid Filter
LFluid Supply Line Shutoff Valve
MFluid Pressure Regulator
NFluid Supply Line
OGun Air Line Filter/Water Separator
PGun Air Supply Line Shutoff Valve
Q* | Air Hose Ground Wire |
R* | Graco Grounded Air Hose |
SElectrostatic Air Spray Gun
TAir Line Drain Valve
U* Fluid Drain Valve
VGun Air Inlet
WGun Fluid Inlet
*Required for safe operation. Must be purchased separately. NOTE: Solenoid valve (B) is not offered as a Graco accessory.
8 | 309292L |