Haier 309292L important safety instructions Spray Pattern Troubleshooting

Page 21

Troubleshooting

Troubleshooting

WARNING

Electric Shock Hazard

Installing and servicing this equipment requires access to parts which may cause an electric shock or other serious injury if the work is not performed properly. Do not install or repair this equipment unless you are trained and qualified.

WARNING

Pressurized Equipment Hazard

To reduce the risk of an injury, follow the Pressure Relief Procedure on page 24 whenever you are instructed to relieve the pressure.

Check all possible remedies in the Troubleshooting Chart before disassembling the gun.

Spray Pattern Troubleshooting

Some spray pattern problems are caused by the improper balance between air and fluid.

Problem

Cause

Solution

 

 

 

Fluttering or spitting spray.

No fluid.

Refill supply.

 

 

 

 

Loose, dirty, damaged nozzle/seat.

Clean or replace nozzle, page 26.

 

Air in fluid supply.

Check fluid source. Refill.

Improper spray pattern.

Damaged nozzle or air cap.

Replace, page 26.

 

Fluid buildup on air cap or nozzle.

Clean. See Operation Manual.

 

Fan air pressure too high.

Decrease.

 

Fluid too thin.

Increase viscosity.

 

Fluid pressure too low.

Increase.

 

Fan air pressure too low.

Increase.

 

Fluid too thick.

Reduce viscosity.

 

Too much fluid.

Decrease flow.

 

 

 

Streaks.

Did not apply 50% overlap.

Overlap strokes 50%.

 

 

 

 

Dirty or damaged air cap.

Clean or replace, page 26.

309292L

21

Image 21
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Symbols Fire, Explosion, and Electric Shock HazardToxic Fluid Hazard Pressurized Equipment Hazard Equipment Misuse HazardIntroduction How the Electrostatic Air Spray Gun WorksGun Overview Install the System InstallationVentilate the Spray Booth Flammable or Toxic Vapor HazardTypical Installation Key Connect the Exhaust Tube Connect the Air LineElectric Shock Hazard Supply HoseFilter the Fluid Connect the Fluid LineSelect a Fluid Nozzle and Air Cap Orifice Size244919 Conversion Kit HC Conversion KitGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityLow Voltage Adjustment Smart Guns Only OperationKV Guns Flush the Spray Gun MaintenanceHang the gun from its hook, with the nozzle pointing down Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceSpray Pattern Troubleshooting TroubleshootingGun Operation Troubleshooting Electrical Troubleshooting See Test Gun Resistance onSee Check Fluid Resistivity on Repair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementFluid Tube Removal Replacement PRO Xs4 Guns Only Turbine Alternator Removal and ReplacementFan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairES ON/OFF Valve Repair Atomizing Air Restrictor Valve Removal and ReplacementParts Ref. No Alternator Ref. No Fan Adjustment Valve Ref. No Packing Rod Ref. No ES ON/OFF ValveFluid Tube Model Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Accessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataTechnical Data 309292L Graco Standard Warranty Graco InformationToll Free