Connect the Air Line

WARNING

Electric Shock Hazard

To reduce the risk of electric shock or other serious injury, the air supply hose must be electrically connected to a true earth ground. Use only Graco Grounded Air

Supply Hose.

1.Connect the Graco Grounded Air Supply Hose (R) between the air supply line and the gun's air inlet

(V). The gun air inlet fitting has a left-hand thread. Connect the air supply hose ground wire (Q) to a true earth ground.

2.Install an air line filter/water separator (O) on the gun air line to ensure a dry, clean air supply to the gun. Dirt and moisture can ruin the appearance of your finished workpiece and can cause the gun to malfunction.

3.Install a bleed-type air regulator (G) on the pump and gun air supply lines to control air pressure to the pump and gun.

Installation

4.Install a bleed-type air valve (E) on the pump air line to shut off air to the pump. Install an additional bleed-type air valve (C) on the main air line (A) to isolate the accessories for servicing.

WARNING

Pressurized Equipment Hazard

The bleed-type air valve (E) is required in your system to relieve air trapped between the valve and the pump after the air regula- tor is shut off. Trapped air can cause the pump to cycle unexpectedly, which can result in serious injury, including splashing fluid in the eyes or on the skin.

5.Install an air shutoff valve ( P) on each gun air sup- ply line to shut off air to the gun(s).

Connect the Exhaust Tube

Press the exhaust tube (38) onto the barbed adapter on the bottom of the gun handle. Secure the tube with the clamp (39).

309292L

9

Image 9
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Symbols Fire, Explosion, and Electric Shock HazardToxic Fluid Hazard Pressurized Equipment Hazard Equipment Misuse HazardIntroduction How the Electrostatic Air Spray Gun WorksGun Overview Install the System InstallationVentilate the Spray Booth Flammable or Toxic Vapor HazardTypical Installation Key Connect the Exhaust Tube Connect the Air LineElectric Shock Hazard Supply HoseFilter the Fluid Connect the Fluid LineSelect a Fluid Nozzle and Air Cap Orifice Size244919 Conversion Kit HC Conversion KitGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityLow Voltage Adjustment Smart Guns Only OperationKV Guns Flush the Spray Gun MaintenanceHang the gun from its hook, with the nozzle pointing down Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceSpray Pattern Troubleshooting TroubleshootingGun Operation Troubleshooting Electrical Troubleshooting See Test Gun Resistance onSee Check Fluid Resistivity on Repair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementFluid Tube Removal Replacement PRO Xs4 Guns Only Turbine Alternator Removal and ReplacementFan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairES ON/OFF Valve Repair Atomizing Air Restrictor Valve Removal and ReplacementParts Ref. No Alternator Ref. No Fan Adjustment Valve Ref. No Packing Rod Ref. No ES ON/OFF ValveFluid Tube Model Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Accessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataTechnical Data 309292L Graco Standard Warranty Graco InformationToll Free