Haier 309292L Connect the Fluid Line, Filter the Fluid, Select a Fluid Nozzle and Air Cap

Page 10

Installation

Connect the Fluid Line

1.Before connecting the fluid line (N), blow it out with air and flush it with solvent. Use solvent which is compatible with the fluid to be sprayed.

2.Install a fluid regulator (M) on the fluid line to control fluid pressure to the gun.

3.Install a fluid filter (K) and drain valve (U) at the pump outlet.

WARNING

Pressurized Equipment Hazard

The fluid drain valve (U) is required in your system to assist in relieving fluid pressure in the displacement pump, hose, and gun.

Triggering the gun to relieve pressure may not be sufficient. Install a drain valve close to the pump's fluid outlet. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin.

4.Connect the fluid line to the 3/8 npsm gun fluid inlet

(W).

5.Before running any paint through the spray gun, flush it out with a compatible solvent.

WARNING

Pressurized Equipment Hazard

To reduce the risk of an injury, follow the Pressure Relief Procedure on page 24 before removing or installing a fluid nozzle and/or air cap.

 

Table 1: Fluid Nozzles

 

 

 

Part No.

 

Orifice Size

 

 

 

197263

 

0.75 mm (.030 in.)

 

 

 

197264

 

1.0 mm (.042 in.)

 

 

 

197265

 

1.2 mm (.047 in.)

 

 

 

197266

 

1.5 mm (.055 in.)

 

 

 

197267

 

1.8 mm (.070 in.)

 

 

 

197268

 

2.0 mm (.080 in.)

 

 

 

249920*

 

0.75 mm (.030 in.)

 

 

 

249921*

 

1.0 mm (.042 in.)

 

 

 

249922*

 

1.2 mm (.047 in.)

 

 

 

249923*

 

1.5 mm (.055 in.)

 

 

 

249924*

 

1.8 mm (.070 in.)

 

 

 

249925*

 

2.0 mm (.080 in.)

 

 

 

* Glass-reinforced acetal construction.

Filter the Fluid

Install a fluid filter (K) to remove particles and sediment which could clog the spray nozzle.

Select a Fluid Nozzle and Air Cap

The gun is supplied with Part No. 197266 Nozzle and 197477 Air Cap. If you require a different size, refer to Table 1 and Table 2 , and instruction manual 309419, or consult with your Graco distributor. See Air Cap/Nozzle Replacement on page 26.

Table 2: Air Caps

 

Pattern Shape

Recommended Fluids and

Part No.

and Length

Production Rates

 

in. (mm)

 

 

 

 

 

197477

Round end;

Light to medium viscosity.

15-17 (381-432)

Medium to high production.

 

 

 

 

197478

Round end;

Light to medium viscosity.

15-17 (381-432)

Low to medium production.

 

 

 

 

197479

Tapered end;

Light to medium viscosity.

13-15 (330-381)

Medium to high production.

 

 

 

 

 

Round end;

Medium to high viscosity

197480

and high solids.

16-18 (406-457)

 

Low to medium production.

 

 

 

 

 

 

 

Medium to high viscosity

197481

Tapered end;

and high solids.

17-19 (432-483)

Medium to high production.

 

 

 

For use with 2.0 mm nozzle.

 

 

 

10

309292L

Image 10
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Fire, Explosion, and Electric Shock Hazard SymbolsToxic Fluid Hazard Equipment Misuse Hazard Pressurized Equipment HazardHow the Electrostatic Air Spray Gun Works IntroductionGun Overview Ventilate the Spray Booth InstallationInstall the System Flammable or Toxic Vapor HazardTypical Installation Key Electric Shock Hazard Connect the Air LineConnect the Exhaust Tube Supply HoseSelect a Fluid Nozzle and Air Cap Connect the Fluid LineFilter the Fluid Orifice SizeHC Conversion Kit 244919 Conversion KitGrounding Check Electrical Grounding Check Gun GroundingCheck Fluid Resistivity Check Fluid ViscosityOperation Low Voltage Adjustment Smart Guns OnlyKV Guns Maintenance Flush the Spray GunHang the gun from its hook, with the nozzle pointing down Electrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceTroubleshooting Spray Pattern TroubleshootingGun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingSee Check Fluid Resistivity on Pressure Relief Procedure RepairPrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fluid Tube Removal Replacement PRO Xs4 Guns OnlyFan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts Ref. No Packing Rod Ref. No ES ON/OFF Valve Ref. No Alternator Ref. No Fan Adjustment ValveFluid Tube Model Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Air Line Accessories AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataTechnical Data 309292L Graco Information Graco Standard WarrantyToll Free