Haier 309292L important safety instructions Air Cap/Nozzle Replacement

Page 26

Repair

Air Cap/Nozzle Replacement

CAUTION

Hold the front end of the gun up and trigger the gun while removing the nozzle to help drain the gun and prevent any paint or solvent left in the gun from entering the air passages.

1.Prepare gun for service, page 25.

2.Remove the retaining ring (27) and air cap (9). See FIG. 11..

3.Point gun up and squeeze trigger while removing the fluid nozzle (7) assembly with the multi-tool (37).

27

27a*

9

37

7

7a

7b

ti1501a

Fig. 11. Air Cap/Nozzle Replacement

WARNING

Fire, Explosion, and Electric Shock Hazard

The nozzle contact ring (7a) is a conductive contact ring, not a sealing o-ring. To reduce the risk of sparking or electric shock, do not remove the nozzle contact ring (7a) except to replace it and never operate the gun with- out the contact ring in place. Do not replace the contact ring with anything but a genuine Graco part.

Use non-silicone grease, Part No. 111265, on the small o-ring (7b). Do not over-lubricate. Do not lubricate the contact ring (7a).

4.Lightly lubricate the o-ring (7b). Install it and the contact ring (7a) on the nozzle (7).

Make sure the electrode needle (29) is finger- tight (page 27).

5.Trigger gun while installing the fluid nozzle (7) with the multi-tool (37). Tighten until the fluid nozzle seats in the gun barrel (1/8 to 1/4 turn past hand-tight).

6.Install the air cap (9) and retaining ring (27). Make sure the u-cup (27a*) is in place with the lips facing forward.

7.Test gun resistance, page 18.

26

309292L

Image 26
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Toxic Fluid Hazard SymbolsFire, Explosion, and Electric Shock Hazard Equipment Misuse Hazard Pressurized Equipment HazardGun Overview IntroductionHow the Electrostatic Air Spray Gun Works Ventilate the Spray Booth InstallationInstall the System Flammable or Toxic Vapor HazardTypical Installation Key Electric Shock Hazard Connect the Air LineConnect the Exhaust Tube Supply HoseSelect a Fluid Nozzle and Air Cap Connect the Fluid LineFilter the Fluid Orifice SizeHC Conversion Kit 244919 Conversion KitGrounding Check Electrical Grounding Check Gun GroundingCheck Fluid Resistivity Check Fluid ViscosityKV Guns Low Voltage Adjustment Smart Guns OnlyOperation Maintenance Flush the Spray GunHang the gun from its hook, with the nozzle pointing down Electrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceTroubleshooting Spray Pattern TroubleshootingGun Operation Troubleshooting See Check Fluid Resistivity on Electrical TroubleshootingSee Test Gun Resistance on Pressure Relief Procedure RepairPrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fluid Tube Removal Replacement PRO Xs4 Guns OnlyFan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts Fluid Tube Model Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF Valve Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Fluid Line Accessories AccessoriesAir Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataTechnical Data 309292L Toll Free Graco Standard WarrantyGraco Information