Fluid Adjustment Valve Repair

1.Prepare the gun for service, page 25.

2.Remove the fluid adjustment valve (25). It can only be replaced as a complete assembly. See FIG. 20..

3.Screw the valve (25) into the gun handle. Torque to 15-25 in-lb (1.7-2.8 N•m).

25

ti1507a

Fig. 20. Fluid Adjustment Valve

4.Remove the air valve (21) with a pliers. Inspect the rubber sealing surface and replace the air valve if damaged.

CAUTION

When removing the air valve (21) be careful not to damage the seat area.The rubber seal is not removable.

5.Inspect the u-cup (6*). Do not remove the u-cup unless damaged. If removed, install the new one with its lips facing into the gun handle (17).

6.Install the air valve (21) and spring (15) into the gun handle (17).

7.Install the fluid adjustment valve (25). Torque to 15-25 in-lb (1.7-2.8 N•m).

8.Install the barrel, page 30.

Air Valve Repair

1.Prepare the gun for service, page 25.

2.Remove the barrel, page 30.

3.Remove the fluid adjustment valve (25) from the handle (17). Remove the spring (15). See FIG. 21..

CAUTION

Clean all parts in non-conductive solvent compati- ble with the fluid being used, such as xylol or min- eral spirits. Use of conductive solvents can cause the gun to malfunction.

21 15

17

*6

ti1512a

Fig. 21. Air Valve

25

34

309292L

Image 34
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Fire, Explosion, and Electric Shock Hazard SymbolsToxic Fluid Hazard Equipment Misuse Hazard Pressurized Equipment HazardHow the Electrostatic Air Spray Gun Works IntroductionGun Overview Ventilate the Spray Booth InstallationInstall the System Flammable or Toxic Vapor HazardTypical Installation Key Electric Shock Hazard Connect the Air LineConnect the Exhaust Tube Supply HoseSelect a Fluid Nozzle and Air Cap Connect the Fluid LineFilter the Fluid Orifice SizeHC Conversion Kit 244919 Conversion KitGrounding Check Electrical Grounding Check Gun GroundingCheck Fluid Resistivity Check Fluid ViscosityOperation Low Voltage Adjustment Smart Guns OnlyKV Guns Maintenance Flush the Spray GunHang the gun from its hook, with the nozzle pointing down Electrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceTroubleshooting Spray Pattern TroubleshootingGun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingSee Check Fluid Resistivity on Pressure Relief Procedure RepairPrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fluid Tube Removal Replacement PRO Xs4 Guns OnlyFan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts Ref. No Packing Rod Ref. No ES ON/OFF Valve Ref. No Alternator Ref. No Fan Adjustment ValveFluid Tube Model Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Air Line Accessories AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataTechnical Data 309292L Graco Information Graco Standard WarrantyToll Free