Haier 309292L Atomizing Air Restrictor Valve Removal and Replacement, ES ON/OFF Valve Repair

Page 35

Atomizing Air Restrictor Valve Removal and Replacement

1.Prepare the gun for service, page 25.

2.Remove the atomizing air restrictor valve (23) . Inspect the o-ring (23c*). Replace if necessary. See FIG. 22..

3.Install a new atomizing air restrictor valve (23), or disassemble and replace parts individually. The valve protrusion must be oriented to clear the air valve (21) shaft.

If the atomizing air restrictor valve is not desired, install the supplied plug (47).

4.Torque the valve housing (23a) to 15-20 in-lb (1.7-2.3 N•m).

23c* 47

23a

23d

23b

ti1508a

Fig. 22. Atomizing Air Restrictor Valve

Repair

ES ON/OFF Valve Repair

1.Prepare the gun for service, page 25.

2.Loosen the screw (48). Remove the valve.

3.Lubricate the o-rings (22a* and 22b*) with non-sili- cone grease, Part No. 111265. Do not over-lubri- cate.

CAUTION

Do not over-lubricate parts. Excessive lubricant on the o-rings can be pushed into the gun air passage and blemish the finish on the workpiece.

4.Clean and inspect parts for damage. Replace if nec- essary.

The protrusion on the retainer plate (22d) must point upward.

5.Reinstall the valve. Torque the screw (48) to 15-25 in-lb (1.7-2.8 N•m).

22d

22f

22g

22e

22b*

22c

22a*

48

TI1488A

Fig. 23. ES ON/OFF Valve

309292L

35

Image 35
Contents PRO Xs3 and PRO Xs4 Air Spray Guns Table of Contents List of Models Toxic Fluid Hazard SymbolsFire, Explosion, and Electric Shock Hazard Pressurized Equipment Hazard Equipment Misuse HazardGun Overview IntroductionHow the Electrostatic Air Spray Gun Works Flammable or Toxic Vapor Hazard InstallationInstall the System Ventilate the Spray BoothTypical Installation Key Supply Hose Connect the Air LineConnect the Exhaust Tube Electric Shock HazardOrifice Size Connect the Fluid LineFilter the Fluid Select a Fluid Nozzle and Air Cap244919 Conversion Kit HC Conversion KitGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityKV Guns Low Voltage Adjustment Smart Guns OnlyOperation Flush the Spray Gun MaintenanceHang the gun from its hook, with the nozzle pointing down Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance Test Electrode ResistanceSpray Pattern Troubleshooting TroubleshootingGun Operation Troubleshooting See Check Fluid Resistivity on Electrical TroubleshootingSee Test Gun Resistance on Repair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementFluid Tube Removal Replacement PRO Xs4 Guns Only Turbine Alternator Removal and ReplacementFan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairES ON/OFF Valve Repair Atomizing Air Restrictor Valve Removal and ReplacementParts Fluid Tube Model Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF Valve Description Qty Description Qty 51 Ref Ref. No ES ON/OFF Valve Ref. No Packing Rod Part No. Description Qty Part No. Description Qty Fluid Line Accessories AccessoriesAir Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataTechnical Data 309292L Toll Free Graco Standard WarrantyGraco Information