Shutdown & Cleaning - After Direct Immersion Method Applications
Power Flush
Power flushing is a faster method of flushing. It can only be used after spraying
1.Relieve pressure, page 7.
2.If you used a spray gun, remove tip and guard assembly from gun and place in flushing fluid.
If you used a roller, leave roller assembly attached to gun.
3.Place waste and paint pails side by side.
ti9726a
4.Lift suction tube and prime tube from paint pail. Let them drain into paint for a while.
5.Place suction and prime tubes in waste pail.
6.Screw power flush attachment to garden hose. Close valve.
ti9413a
7.Turn on water. Open valve. Rinse paint off suction tube, prime tube and inlet screen.
9.Unscrew inlet screen from suction tube. Place inlet screen in waste pail.
TIA
10.Connect suction tube to Power Flush attachment. Leave prime
tube in waste pail.
TIA
11.Open lever on Power Flush attachment.
OPEN
TIA
12.Turn AllControl to
PRIME/CLEAN PUMP.
ti9169a
8. Turn lever to close power flush attachment.
ti9727a
13.Circulate water through sprayer, into waste pail for 20 seconds.
14. Turn AllControl to OFF.
ti9168a
26 | 312079A |