Shutdown and Cleaning
6.Disconnect trigger lock and trigger sprayer for approximately 15 seconds. Engage trigger lock.
10.Engage trigger lock and put prime/relief valve UP to release pressure.
ti14994a
7.Discard contaminated fluid and refill with appropri- ate flushing fluid.
8.Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer.
ti1495a
ti14991a
9.Put prime/relief valve DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.
ti14994a
11.Remove material cup and discard used fluid.
12.Use a soft brush to clean the black rubber inlet seal. If the vent holes become clogged, use the fine finish optimizer cleaning tool or a paper clip to clear the holes.
| 13. Remove Spray Tip/Guard Assembly and clean with | |
ti15425a | water or flushing fluid. A soft brush can be used to | |
loosen and remove dried material if needed. | ||
ti15491a |
To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.
ti15529a
Keep spray area
NOTICE
The tip is permanently attached to the guard. Remov- ing the tip from the guard will result in damage to the tip assembly.
14.Replace tip assembly.
15.If you used the
3A0705E | 15 |