Graco 258880, 258864 important safety instructions Inlet Valve Cleaning, Removal

Page 22

Inlet Valve Cleaning

Removal

1.Engage trigger lock and pull relief valve UP to release pressure.

ti14994a

ti14999a

2. Remove material cup and suction tube.

3.Hold sprayer upside-down and use wrench or socket to loosen and remove inlet fitting, inlet valve, and spring.

ti15505a

NOTE: Make sure the spring also comes out. Use needle-nose pliers to remove if needed. Inlet cavity should be completely empty (as shown below).

ti15530a

Inlet Valve Cleaning

4.Clean as much excess material from pump cavity as possible. Make sure you also clean spring (a), o-ring (c), and top of inlet fitting (d).

Installation

NOTE: Before installing, make sure o-ring (c) is installed on inlet valve (b).

1.Place inlet valve (b) with spring (a) on top of inlet fit- ting (d). Push inlet fitting up into pump cavity.

a

b c

d

ti15502a

2.Hold inlet in place and turn sprayer upside-down. Remove inlet fitting and visually check to see that inlet valve has seated correctly.

3.Replace inlet fitting and use wrench and socket to tighten to 10 ft-lb.

NOTICE

Do NOT over-tighten inlet fitting. Damage to the equipment will occur.

4.Use your Fine-Finish Optimizer cleaning tool to lightly push on inlet valve to make sure it moves up and down freely.

22

3A0705E

Image 22
Contents 3A0705E Table of Contents Fire and Explosion Hazard Battery Hazard Component Identification Trigger Lock Pressure Relief ProcedurePrime/Relief Valve Position Charger Status Indicator Lights Charging the BatterySprayer Status Indicator Installation SetupInstalling Suction Tube Cleanup/StorageSprayer Setup Materials Starting a New Job or Refilling the CupInstall Tip/Guard Assembly if not installed Reversible Tip Selection ChartTriggering Sprayer Aiming SprayerUnclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerWater or flushing fluid. a soft brush can be used to Storage Cleaning Sprayer ExteriorTips Replacement Parts and Kits Ref. Part DescriptionTroubleshooting Problem Cause SolutionSpray Pattern Diagnostics Problem Cause Solution Replace tip. See Install Tip/Guard AssemSpray pattern spits at Alternate Priming Method Inlet Valve Cleaning RemovalTechnical Data SprayerGraco Standard Warranty Graco Information