Setup
Sprayer Setup
This sprayer arrives from the factory with a small amount of test material in the system. It is important that you flush this material from the sprayer before using it for the first time:
1. Fill material cup with water and thread onto sprayer.
ti14992a
5.Engage trigger lock and put prime/relief valve UP to release pressure.
ti14994a | ti14999a |
6.Unscrew and remove material cup.
7.Disengage trigger lock, put prime/relief valve DOWN, hold sprayer slightly above material cup, and pull trigger to discharge fluid from pump.
2.Put prime/relief valve to UP position, then hold trig- ger in for 10 seconds.
ti14999a
3. Put prime/relief valve DOWN to spray position.
ti15425a
4.Reverse spray tip to UNCLOG position and trigger sprayer into a waste area.
ti14991a | ti15491a |
ti15478a
8. Discard material in cup.
NOTE: If the sprayer is angled or tilted too far, the suction tube will lose contact with the material and the sprayer will stop spraying.
ti15511a