Alternate Priming Method
Alternate Priming Method
1.Engage trigger lock and put prime/relief valve UP to release pressure.
ti14994a | ti14999a |
2. Remove material cup and fill with flushing material.
4.Hold sprayer above sink or waste area, disengage the trigger lock, and quickly trigger sprayer until material comes out of the drain tube.
ti14995a
ti14991a
NOTE: Material can shoot out of the drain tube when performing this procedure. Be sure to wear appropriate safety equipment and point drain tube away from yourself when pulling the trigger,
5. Thread the material cup back onto sprayer.
3.With sprayer in prime mode, turn sprayer
6.Trigger the gun for 10 seconds then release the trig- ger and put the prime/relief valve DOWN to spray position.
ti15425a
7.Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.
ti14995a
ti14991a
8.Sprayer is now ready to spray. Follow Starting New Job instructions on page 10.
3A0705E | 21 |