Carrier 40RMQ008-028, 40RM007-034, 40RMS008-034 specifications Unit Airflow Pressure Drop

Page 45

Legend and Notes for Tables 11A and 11C

LEGEND

Bhp — Brake Horsepower Input to Fan

ESP — External Static Pressure

NOTES:

1.Maximum allowable fan speed is 1100 rpm for unit sizes 028 and 034; 1200 rpm for all other sizes.

2.Fan performance is based on deductions for wet coil, clean 2-in. filters, and unit casing. See table at right for factory-supplied filter pressure drop.

3.Refer to fan motor and drive tables for additional data.

FACTORY-SUPPLIED PRESSURE DROP — ENGLISH

UNIT

AIRFLOW

PRESSURE DROP

(Cfm)

(in. wg)

 

40RM

1,800

0.05

2,400

0.08

007

3,000

0.11

 

40RM

2,250

0.07

40RMQ

3,000

0.11

40RMS

3,750

0.15

008

 

 

40RMS

2,550

0.09

3,400

0.13

010

4,250

0.18

 

40RM

3,000

0.11

40RMQ

4,000

0.17

40RMS

5,000

0.23

012

 

 

40RM

3,750

0.06

40RMS

5,000

0.10

014

6,250

0.13

40RM

4,500

0.08

40RMQ

6,000

0.12

40RMS

7,500

0.17

016

 

 

40RM

6,000

0.12

40RMQ

8,000

0.19

40RMS

10,000

0.26

024

 

 

40RM

7,500

0.15

40RMQ

10,000

0.22

40RMS

12,500

0.30

028

 

 

40RM

9,000

0.19

40RMS

12,000

0.29

034

15,000

0.40

Legend and Notes for Tables 11B and 11D

LEGEND

FACTORY-SUPPLIED PRESSURE DROP — SI

ESP — External Static Pressure

 

 

 

NOTES:

UNIT

AIRFLOW

PRESSURE DROP

(L/s)

(Pa)

 

1. Maximum allowable fan speed is 18.3 r/s for unit sizes 028 and

 

 

 

40RM

850

13

034; 20 r/s for all other sizes.

1150

20

2. Fan performance is based on deductions for wet coil, clean

007

1450

28

51-mm filters, and unit casing. See table at right for factory-sup-

 

40RM

 

 

plied filter pressure drop.

1000

17

3. Refer to fan motor and drive tables for additional data.

40RMQ

1400

27

 

40RMS

 

1800

38

 

008

 

 

 

 

40RMS

1200

21

 

1600

32

 

010

 

2000

45

 

 

 

40RM

1450

28

 

40RMQ

 

1900

42

 

40RMS

 

2350

56

 

012

 

 

 

 

40RM

1750

15

 

40RMS

2350

24

 

014

2950

33

 

40RM

2100

20

 

40RMQ

 

2800

30

 

40RMS

 

3500

42

 

016

 

 

 

 

40RM

2900

32

 

40RMQ

 

3800

47

 

40RMS

 

4700

64

 

024

 

 

 

 

40RM

3500

36

 

40RMQ

 

4700

55

 

40RMS

 

5900

76

 

028

 

 

 

 

40RM

4250

47

 

40RMS

5650

71

 

034

7050

98

45

Image 45
Contents Installation, Start-Up Service Instructions Installation 40RM Physical Data, English Cooling Units Unit 40RMQ 40RMQ Physical Data, English Heat Pump Units008 012 016 024 028 Nominal Capacity Tons No. of Splits No. of Circuits per SplitUnit 40RMS 40RMS Physical Data, English Chilled Water UnitsUnit 40RM 40RM Physical Data, SI Cooling Units40RMQ Physical Data, SI Heat Pump Units 40RMS Physical Data, SI Chilled Water Units Unit Unit Weight 40RM016 40RM01440RM024 40RMQ01640RM034 40RM02840RMQ028 40RMS028Unit 40RM 016 - B 5 0 1 GC007 008 010 012 014 016 024 028 034 40RM 40RMQ 40RMSTypical Unit Positioning Preferred Suspension Technique Refrigerant and Chilled Water Piping Access Holes TXV Sensing Bulb Location Fitting Requirements Factory-Installed Nozzle and Distributor Data014-024 Typical 40RMS Chilled Water Piping Condensate Drains Cover Removed Typical Wiring and Service Access Side Panel RemovedMocp Electrical Data, Standard MotorsMocp Electrical Data, Alternate MotorsGND EquipHTR IFCManufacturer Lubricant Lubricant DataFan Shaft Bearing Fan Pulley Alignment Align as follows Filter Removal/Replacement Fan Motor Data, Standard Motor English Fan Motor Data, Alternate Motor English40RMS 40RMQ Fan Motor Data, Alternate Motor SI Fan Motor Data, Standard Motor SIMedium-Static Drive Data, 60 Hz English Standard Drive Data, 60 Hz EnglishStandard Drive Data, 60 Hz SI High-Static Drive Data, 60 Hz EnglishMedium-Static Drive Data, 60 Hz SI High-Static Drive Data, 60 Hz SI008 012 016 024 028 Medium-Static Drive Data, 50 Hz English Standard Drive Data, 50 Hz English40RMQ Unit Unit 40RMQ 40RMSHigh-Static Drive Data, 50 Hz English Standard Drive Data, 50 Hz SI014 034 008 012 016 024 High-Static Drive Data, 50 Hz SI Medium-Static Drive Data, 50 Hz SIRMQ Unit AirflowRpm Bhp 800 External Static Pressure in. wg 40RM Cfm007 400 008 000100 150 200 250 300 External Static Pressure kPa850 990350 400 450 500 550 600 016 300 008 600921 975 1026 008 1420 External Static Pressure kPa 100 150 200 250 300016 2830 024 3300External Static Pressure kPa 350 400 450 500 550 600 Unit Airflow Pressure Drop Copyright 2004 Carrier Corporation Preliminary Information Comp A1 Comp B1 Check Voltage Imbalance