Carrier 40RM007-034 Standard Drive Data, 50 Hz English, Medium-Static Drive Data, 50 Hz English

Page 34

Table 10A — Standard Drive Data, 50 Hz — English

 

 

40RM

 

40RM

40RM

40RM

40RM

40RM

40RM

 

40RM

40RMQ

40RMS

40RMQ

40RMQ

40RMQ

40RMQ

UNIT

40RMS

40RMS

007

40RMS

010

40RMS

40RMS

40RMS

40RMS

 

014

034

 

 

008

 

012

016

024

028

 

 

 

 

 

 

MOTOR DRIVE

 

 

 

 

 

 

 

 

 

 

 

Motor Pulley Pitch Diameter (in.)

2.4-3.4

2.8-3.8

2.8-3.8

3.4-4.4

3.4-4.4

3.4-4.4

4.3-5.3

4.3-5.3

4.3-5.3

Pulley Factory Setting

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

Full Turns Open

 

 

 

 

 

 

 

 

 

 

 

FAN DRIVE

 

 

 

 

 

 

 

 

 

 

 

Pulley Pitch Dia (in.)

8.0

8.0

8.0

8.0

9.0

9.0

8.6

11.0

11.0

Pulley Bore (in.)

1

1

1

1

17/

17/

17/

115/

16

115/

16

 

 

 

 

 

16

16

16

 

 

Belt No. — Section

1—A

1—A

1—A

1—A

1—A

1—A

1—B

2—B

2—B

Belt Pitch (in.)

39.3

39.3

39.3

40.3

42.3

42.3

41.8

43.8

43.8

FAN SPEEDS (rpm)

 

 

 

 

 

 

 

 

 

 

 

Factory Setting

517

588

588

695

618

618

795

622

622

Range

428-606

499-677

449-677

606-784

538-697

538-697

713-878

557-687

557-687

Max Allowable Speed (rpm)

1200

1200

1200

1200

1200

1200

1200

1100

1100

Change per 1/ Turn of

 

 

 

 

 

 

 

 

 

 

 

2

17.8

17.8

17.8

17.8

15.9

15.9

13.8

10.8

10.8

Moveable Motor Pulley

Flange

 

 

 

 

 

 

 

 

 

 

 

MAX FULL TURNS FROM

5

5

5

5

5

5

6

6

 

6

 

CLOSED POSITION

 

 

 

 

 

 

 

 

 

 

 

 

 

SHAFTS CENTER DISTANCE (in.)

10.44-

10.44-

10.44-

10.44-

10.44-

10.44

9.12-

6.67-

6.67-

 

12.32

12.32

12.32

12.32

12.32

12.32-

10.99

9.43

9.43

Table 10B — Medium-Static Drive Data, 50 Hz — English

 

40RM

40RM

 

40RM

40RM

40RM

40RM

40RM

40RM

UNIT

40RMQ

40RMS

40RMQ

40RMQ

40RMQ

40RMQ

40RMS

40RMS

007

40RMS

010

40RMS

40RMS

40RMS

40RMS

 

014

034

 

 

008

 

012

016

024

028

 

 

 

 

 

MOTOR DRIVE

 

 

 

 

 

 

 

 

 

Motor Pulley Pitch Diameter (in.)

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.4-4.4

3.7-4.7

4.0-5.0

4.3-5.3

4.3-5.3

Pulley Factory Setting

2.5

2.5

2.5

2.5

2.5

3.0

2.5

3.0

3.0

Full Turns Open

 

 

 

 

 

 

 

 

 

FAN DRIVE

 

 

 

 

 

 

 

 

 

Pulley Pitch Dia (in.)

8.0

7.0

7.0

6.0

7.5

7.9

7.0

9.4

9.4

Pulley Bore (in.)

1

1

1

1

17/16

17/16

17/16

115/16

115/16

Belt No. — Section

1—A

1—A

1—A

1—A

1—A

1—B

2—A

2—B

2—B

Belt Pitch (in.)

40.3

41.3

41.3

37.3

39.3

39.8

36.8

39.8

39.8

FAN SPEEDS (rpm)

 

 

 

 

 

 

 

 

 

Factory Setting

695

794

794

926

741

756

916

728

728

Range

606-784

692-896

692-896

808-1045

646-836

667-848

814-1018

652-803

652-803

Max Allowable Speed (rpm)

1200

1200

1200

1200

1200

1200

1200

1100

1100

Change per 1/ Turn of

 

 

 

 

 

 

 

 

 

2

17.8

20.4

20.4

23.7

19.0

15.1

20.4

12.6

12.6

Moveable Motor Pulley

Flange

 

 

 

 

 

 

 

 

 

MAX FULL TURNS FROM

5

5

5

5

5

6

5

6

6

CLOSED POSITION

 

 

 

 

 

 

 

 

 

SHAFTS CENTER DISTANCE (in.)

10.44-

10.44-

10.44-

10.44-

10.44-

9.16-

9.16-

6.67-

6.67-

 

12.32

12.32

12.32

12.32

12.32

10.99

10.99

9.43

9.43

34

Image 34
Contents Installation, Start-Up Service Instructions Installation 40RM Physical Data, English Cooling Units 008 012 016 024 028 Nominal Capacity Tons 40RMQ Physical Data, English Heat Pump UnitsUnit 40RMQ No. of Splits No. of Circuits per Split40RMS Physical Data, English Chilled Water Units Unit 40RMS40RM Physical Data, SI Cooling Units Unit 40RM40RMQ Physical Data, SI Heat Pump Units 40RMS Physical Data, SI Chilled Water Units Unit Unit Weight 40RM024 40RM01440RM016 40RMQ01640RMQ028 40RM02840RM034 40RMS028007 008 010 012 014 016 024 028 034 40RM 40RM 016 - B 5 0 1 GCUnit 40RMQ 40RMSTypical Unit Positioning Preferred Suspension Technique Refrigerant and Chilled Water Piping Access Holes TXV Sensing Bulb Location Factory-Installed Nozzle and Distributor Data Fitting Requirements014-024 Typical 40RMS Chilled Water Piping Condensate Drains Wiring and Service Access Side Panel Removed Cover Removed TypicalElectrical Data, Standard Motors MocpElectrical Data, Alternate Motors MocpHTR EquipGND IFCLubricant Data Manufacturer LubricantFan Shaft Bearing Fan Pulley Alignment Align as follows Filter Removal/Replacement Fan Motor Data, Alternate Motor English Fan Motor Data, Standard Motor English40RMS 40RMQ Fan Motor Data, Standard Motor SI Fan Motor Data, Alternate Motor SIStandard Drive Data, 60 Hz English Medium-Static Drive Data, 60 Hz EnglishHigh-Static Drive Data, 60 Hz English Standard Drive Data, 60 Hz SIHigh-Static Drive Data, 60 Hz SI Medium-Static Drive Data, 60 Hz SI008 012 016 024 028 40RMQ Unit Standard Drive Data, 50 Hz EnglishMedium-Static Drive Data, 50 Hz English Unit 40RMQ 40RMSStandard Drive Data, 50 Hz SI High-Static Drive Data, 50 Hz English014 034 008 012 016 024 Medium-Static Drive Data, 50 Hz SI High-Static Drive Data, 50 Hz SIUnit Airflow RMQ007 400 External Static Pressure in. wg 40RM CfmRpm Bhp 800 008 000850 External Static Pressure kPa100 150 200 250 300 990350 400 450 500 550 600 008 600 016 300921 975 1026 016 2830 External Static Pressure kPa 100 150 200 250 300008 1420 024 3300External Static Pressure kPa 350 400 450 500 550 600 Unit Airflow Pressure Drop Copyright 2004 Carrier Corporation Preliminary Information Check Voltage Imbalance Comp A1 Comp B1