Carrier 50HQP072-120 specifications Blower Data 50HQP096

Page 18

Table 6 — Blower Data — 50HQP096

AIRFLOW

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (Pa)

 

 

 

 

 

 

 

(l/s)

0

25

50

75

100

125

150

175

200

225

 

250

275

300

325

350

375

 

BkW

0.15

0.18

0.21

0.24

0.27

0.30

0.32

0.34

0.36

 

0.39

0.42

0.46

0.49

0.52

0.55

850

Sheave/Mtr

B

B

B

A

A

A

A

A

A

 

C

C

C

C

C

C

RPM

500

552

604

655

700

745

780

820

855

 

890

915

945

970

995

1020

 

 

 

Turns Open

4.5

3

1.5

5.5

4.5

3.5

2.5

2

1

 

4

3.5

3

2.5

2

1.5

 

BkW

0.19

0.21

0.24

0.28

0.31

0.34

0.38

0.41

0.44

0.47

 

0.50

0.53

0.55

0.58

0.61

897

Sheave/Mtr

B

B

A

A

A

A

A

A

A

C

 

C

C

C

C

C

RPM

521

573

625

670

710

755

795

830

870

900

 

930

960

990

1015

1040

 

 

 

Turns Open

4

2.5

6

5

4

3

2.5

1.5

1

3.5

 

3

2.5

2

1.5

1

 

BkW

0.20

0.22

0.25

0.28

0.32

0.36

0.39

0.42

0.46

0.49

 

0.52

0.55

0.58

0.60

0.63

944

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

 

C

C

C

C

C

RPM

500

542

594

640

685

730

770

805

845

880

 

915

945

975

1005

1030

 

 

 

Turns Open

4.5

3.5

2

5.5

4.5

3.5

3

2

1

4

 

3.5

2.5

2

1.5

1

 

BkW

0.24

0.27

0.30

0.33

0.36

0.39

0.43

0.47

0.51

0.54

 

0.57

0.60

0.63

0.66

0.69

991

Sheave/Mtr

B

B

B

A

A

A

A

A

A

C

 

C

C

C

C

C

RPM

516

563

615

655

700

740

780

820

860

895

 

925

960

990

1020

1045

 

 

 

Turns Open

4

3

1.5

5.5

4.5

3.5

2.5

2

1

4

 

3

2.5

2

1

1

 

BkW

0.26

0.29

0.32

0.36

0.40

0.43

0.47

0.51

0.54

0.58

 

0.61

0.64

0.67

0.71

1038

Sheave/Mtr

B

B

A

A

A

A

A

A

C

C

 

C

C

C

C

RPM

536

583

630

670

715

755

795

835

870

905

 

935

970

1000

1030

 

 

 

Turns Open

3.5

2.5

6

5

4

3

2.5

1.5

4

3.5

 

3

2

1.5

1

 

BkW

0.30

0.34

0.37

0.40

0.43

0.47

0.51

0.55

0.59

0.62

 

0.66

0.69

0.73

0.77

1086

Sheave/Mtr

B

B

A

A

A

A

A

A

C

C

 

C

C

C

C

RPM

557

604

650

690

730

770

810

845

885

915

 

950

980

1010

1040

 

 

 

Turns Open

3

2

5.5

4.5

3.5

3

2

1

4

3.5

 

2.5

2

1.5

1

 

BkW

0.34

0.37

0.41

0.44

0.47

0.51

0.56

0.60

0.64

0.67

 

0.71

0.74

0.78

1133

Sheave/Mtr

B

A

A

A

A

A

A

A

C

C

 

C

C

C

RPM

583

625

665

705

745

785

825

860

895

925

 

960

990

1020

 

 

 

Turns Open

2.5

6

5

4

3.5

2.5

1.5

1

4

3

 

2.5

2

1

 

BkW

0.38

0.41

0.44

0.48

0.52

0.56

0.61

0.65

0.69

0.72

 

0.75

0.79

0.83

1180

Sheave/Mtr

B

A

A

A

A

A

A

C

C

C

 

C

C

C

RPM

604

645

685

725

765

800

835

875

905

940

 

970

1005

1030

 

 

 

Turns Open

2

5.5

4.5

4

3

2

1.5

4

3.5

3

 

2

1.5

1

 

BkW

0.41

0.45

0.48

0.51

0.55

0.60

0.64

0.69

0.72

0.76

 

0.80

0.85

1227

Sheave/Mtr

A

A

A

A

A

A

A

C

C

C

 

C

C

RPM

625

665

700

740

775

815

850

885

915

950

 

985

1015

 

 

 

Turns Open

6

5

4.5

3.5

3

2

1

4

3.5

2.5

 

2

1.5

 

BkW

0.45

0.49

0.52

0.56

0.60

0.64

0.68

0.73

0.77

0.81

 

0.85

0.90

1274

Sheave/Mtr

A

A

A

A

A

A

A

C

C

C

 

C

C

RPM

645

685

720

760

795

830

865

900

930

960

 

995

1025

 

 

 

Turns Open

5.5

4.5

4

3

2.5

1.5

1

3.5

3

2.5

 

1.5

1

 

BkW

0.49

0.53

0.57

0.61

0.65

0.69

0.74

0.78

0.82

0.86

 

0.91

0.96

1322

Sheave/Mtr

A

A

A

A

A

A

C

C

C

C

 

C

C

RPM

665

705

745

780

810

845

880

910

945

975

 

1005

1035

 

 

 

Turns Open

5

4

3.5

2.5

2

1

4

3.5

2.5

2

 

1.5

1

 

BkW

0.53

0.57

0.61

0.65

0.69

0.73

0.77

0.82

0.87

0.91

 

0.96

1.02

1369

Sheave/Mtr

A

A

A

A

A

A

C

C

C

C

 

C

C

RPM

685

720

760

795

825

860

890

920

955

985

 

1015

1045

 

 

 

Turns Open

4.5

4

3

2.5

1.5

1

4

3

2.5

2

 

1.5

1

 

BkW

0.58

0.62

0.67

0.71

0.75

0.79

0.84

0.88

0.93

0.97

 

1.03

1416

Sheave/Mtr

A

A

A

A

A

C

C

C

C

C

 

C

RPM

700

735

775

810

845

875

910

940

970

1000

 

1030

 

 

 

Turns Open

4.5

3.5

2.5

2

1

4

3.5

3

2

1.5

 

1

 

BkW

0.64

0.68

0.72

0.76

0.80

0.85

0.90

0.97

1.02

1.07

 

1.12

1463

Sheave/Mtr

A

A

A

A

A

C

C

C

C

C

 

C

RPM

720

755

790

825

860

890

920

955

985

1015

 

1040

 

 

 

Turns Open

4

3

2.5

1.5

1

4

3

2.5

2

1.5

 

1

 

BkW

0.70

0.75

0.80

0.85

0.90

0.94

0.99

1.03

1.08

1.13

 

1510

Sheave/Mtr

A

A

A

A

C

C

C

C

C

C

 

RPM

740

775

810

840

875

905

935

965

995

1025

 

 

 

 

Turns Open

3.5

2.5

2

1.5

4

3.5

3

2.5

1.5

1

 

LEGEND

Operation Not Recommended BkW — Brake Kilowatts

ESP — External Static Pressure RPM — Revolutions Per Minute

A — Units with Standard Static/Standard Motor Option B — Units with Low Static/Standard Motor Option

C — Units with High Static/Standard Motor Option

NOTES:

1.A = Standard Rpm/Standard Motor, B = Low Rpm/Standard Motor, C = High Rpm/Standard Motor.

2.Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.

3.For applications requiring higher static pressures, contact your local rep- resentative. Performance data does not include drive losses and is based on sea level conditions.

4.All airflow is rated at lowest voltage if unit is dual voltage rated, i.e., 380V for 380/420V units.

5.Airflow in l/s with wet coil and clean filter.

18

Image 18
Contents Contents Safety ConsiderationsInstallation GeneralPhysical Data 50HQP072-120 Units Unit Dimensions Typical Horizontal Installation Install Condensate Piping Drain Hanger BracketsRemoving Panels Install Field Power Supply Wiring Supply/Return Hose KitTypical Ground-Water Piping Installation Water Quality Guidelines MaterialFP2 DPPFP1 HpwrSee legend and notes on LWT SATSPT Electrical Data 50HQP072-120 Dual Point Power Units Electrical Data 50HQP072-120 Standard UnitsLow Voltage VA Ratings Install Field Control Wiring Jumper LocationsPRE-START-UP Blower Data 50HQP072 AirflowBlower Data 50HQP096 Blower Data 50HQP120 Complete C Control Jumper Settings See Fig Deluxe D Control Jumper Settings See FigField Selectable Inputs Accessory DIP Switch Position Relay Options DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options OADOperating Limits Unit Start-Up in Cooling ModeSTART-UP Start Up SystemUnit Start-Up in Heating Mode Coaxial Water Pressure DropSize Operation Approximate Fluid Volume L Per 30 M of PipeAntifreeze Percentages by Volume Units with Aquazone Complete C ControlSystem Test Aquazone Deluxe D Control LED IndicaService Fault DescriptionsComplete C Control LED Code Gravity Flow Method a50-8586 Refrigerant Charging Air Coil Fan Motor RemovalSheave Alignment Unit Size Component Drive Package 50HQPTroubleshooting Thermistor Nominal ResistanceTroubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate Page Copyright 2010 Carrier Corporation START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle Analysis