6-3. Connecting Optional Auxiliary Power Plant
14
13
12
11
10
93
91
90
92
15
1
F3
2
F2
3
F1
4
5
9 | 8 | 7 | 6 |
AC | Single |
| Three |
Phase |
| Phase | |
Output |
| ||
1 |
| 3 | |
|
| ||
Volts | 120/240 |
| 240 |
Amps | 31 |
| 24 |
|
|
|
|
KVA/KW | 7.5 |
| 10 |
Frequency |
| 60 Hz | |
|
| ||
Engine Speed | 1850 RPM | ||
Max. Fuse Size | 35 Amperes | ||
|
|
|
|
Lead 42 connects to GROUND stud on front of unit.
Jumper 42 is connected to 90 at factory.
YStop engine.
YPower and weld outputs are live at the same time.
Disconnect or insulate unused cables.
.Have qualified person install according to circuit diagram and Auxiliary Power Guidelines (Section 10).
Remove junction box cover.
1Lead 93
2Lead 92
3Lead 91
4Lead 90 (Neutral)
5Lead 42 (Circuit Grounding Lead)
Lead 42 connects to front panel Ground stud.
6Grounding Terminal
7Jumper Lead 42
8Isolated Neutral Terminal
Jumper 42 is connected to lead 90 at factory. Jumper 42 may be dis- connected from neutral to meet applicable electrical codes.
9Lead 80
10Receptacle RC9 leads
11Lead 42
12Lead 81
13Lead 82
14Load Terminals
Connect leads to terminals.
15 Fuses F1, F2, And F3
F1, F2, and F3 protect each load line from overload.
.Set Engine Control switch to Run when using auxiliary power.
Tools Needed:
Ref.