Delta 50-762, 50-763 instruction manual Functional Description, Carton Contents

Page 6

POWER CONNECTIONS

A separate electrical circuit should be used for your machine. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. Before connecting the machine to the power line, make sure the electric current is of the same characteristics as indicated on the machine's specification plate. All line connections should make good contact. Running on low voltage will damage the machine.

Do not expose the machine to rain or operate the machine in damp locations.

MOTOR SPECIFICATIONS

The 50-762 is wired to run on 230 volts, 60 HZ, but it can also be reconfigured to run on 460 volts. The 50-763 is wired for 230 volts, 60 HZ.

This machine must be grounded while in use to protect the operator from electric shock.

The 50-762 and 50-763 dust collectors do not come with power cords and must be permanently connected to the building’s electrical system and grounded according to the National Electrical Code. You CANNOT use extension cords with these three-phase machines. For instructions on how to wire three-phase or single-phase motors, check the section “SINGLE- AND THREE-PHASE WIRING” in this manual.

460 VOLT OPERATION

460 volt operation of the 50-762 requires replacement of the motor starter and reconfiguration of the motor's internal connections. A 460 volt starter is available from most industrial electrical supply dealers and must be installed by a qualified electrician.

DO NOT ATTEMPT to wire the machine for 460 volts without replacing the starter. Doing so will cause damage to the machine and personal injury could result.

FUNCTIONAL DESCRIPTION

FOREWORD

The Delta Industrial Dust collectors, Models 50-762 and 50-763, connect to woodworking machines that accept a 4" diameter hose. The units each come with four 6 mil plastic collection bags and two 1-micron cloth filter bags. The 50- 762 has a three-phase 230V/460V 3HP motor, while the 50-763 has a single-phase 230V 3HP motor.

CARTON CONTENTS

1

2

1.Motor and Blower Assembly

2.Stand

6

Image 6
Contents 50-762 50-763 Table of Contents Important Safety InstructionsSafety Guidelines Definitions Tool Warning LabelGeneral Safety Rules Stay ALERT, Watch What YOU are DOING, and USEAdditional Specific Safety Rules Carton Contents Functional DescriptionUnpacking and Cleaning Attaching the Legs on the MOTOR/BLOWER Assembly AssemblyAssembly Tools Required Attaching the CastersAlternate SET-UP Attaching the Dust Intake PortsAttaching a Dust Collection BAG Using a Cloth Covered Flexible RingUsing a Metal BAG Clamp Attaching the TOP Filter BAGAttaching the Accessory Hose to the Intake Port SINGLE- and THREE-PHASE WiringModel 50-762 Three Phase Installation 230 Volt Operation Model 50-763 Single Phase Installation Volt OperationOperation Troubleshooting MaintenanceLocking Switch in the OFF Position Starting and Stopping the Dust CollectorWarranty ServiceAccessories Replacement PartsFrançais Conservez CES Instructions LES Instructions Importantes DE SureteMesures DE Sécurité Définitions LA Proposition DE CalifornieRègles DE Sécurité Générales Lutilisation DE CET OutilRègles DE Sécurité Spécifiques Supplémentaires Conserver CES DirectivesCaractéristiques Techniques DU Moteur Description FonctionnelleConnexions Électriques Fonctionnement Avec UNE Tension DE 460 VoltsContenus DE Boite Outils Nécessaires Pour L’ASSEMBLEE AssemblageDésemballage ET Nettoyage Lestimation DE Temps DassembleeFixation DES Roulettes Assemblage DES Pattes AU Module MOTEUR-SOUFFLEURAssemblage DU Socle AUX Pattes DU Module MOTEUR-SOUFFLEUR Assemblage Alternatif Assemblage DE LA Goulotte À PoussièreFixation DU SAC Collecteur DE Poussière Utilisation DE L’ANNEAU Flexible Gainé DE TissuUtilisation DE LA Bride Métallique DU SAC Raccord DU Tuyau Accessoire À L’ORIFICE D’ADMISSION Fixation DU SAC Filtrant SupérieurCâblage DE Moteurs Triphasés OU Monophasés Fonctionnement Avec UNE Tension DE 460 VoltsVerrouiller L’INTERRUPTEUR EN Position D’ARRÊT FonctionnementDémarrage ET Arrêt DU Dépoussiéreur Modèle 50-763, Câblage Pour Moteur MonophaséAccessoiries Depannage EntretienGarantie Español Proposición DE California Instrucciones DE Seguridad ImportantesPautas DE SEGURIDAD/DEFINICIONES Guarde Estas InstruccionesNormas Generales DE Seguridad AIRE, Incluyendo Polvo DE MADERA, Polvo DENormas Específicas Adicionales DE Seguridad Guarde Estas InstruccionesEspecificaciones DEL Motor Descripción FuncionalConexiones Eléctricas Funcionamiento a 460 VoltiosContenido DE Carton Ensamblaje Cómo Colocar LAS RuedasCómo Conectar LAS Patas AL Conjunto DEL Motor Y Soplador Instalación Alternativa Cómo Conectar LOS Orificios DE Admisión DE PolvoCómo Conectar LA Bolsa DE Recolección DE Polvo CON EL Anillo Flexible Cubierto DE TelaCómo Conectar LA Bolsa DE Filtro Superior Cómo Conectar LA Manguera Accesoria AL Orificio DE AdmisiónCableado DE UNA Y Tres Fases Funcionamiento a 460 VoltiosOperación Cómo Encender Y Detener EL Recolector DE PolvoInstalación DE UNA Sola Fase DEL Modelo Localizacion DE Fallas Mantenimiento ServicioAccesorios GarantiaNotas Delta Machinery Highway 45 North Jackson, TN 800