Delta A15098 Additional Specific Safety Rules, Power Connections, Motor Specifications

Page 5

ADDITIONAL SPECIFIC SAFETY RULES

FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS INJURY.

DO NOT USE THIS UNIT TO FILTER METAL DUST. Combining wood and metal dust can create an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only.

DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE. Explosions or fire can result. This dust collector is intended for use where only dry airborne dust is present. Its use should be limited to non-explosive,non-metallic atmospheres.

1.DO NOT OPERATE THIS UNIT UNTIL IT IS COMPLETE- LY ASSEMBLED AND INSTALLED ACCORDING TO THE INSTRUCTIONS. A unit incorrectly assembled can cause injury.

2.OBTAIN ADVICE FROM YOUR SUPERVISOR, IN- STRUCTOR, OR ANOTHER QUALIFIED PERSON if you are not thoroughly familiar with the operation of this unit. Knowledge is safety

3.FOLLOW ALL WIRING CODES and recommended electrical connections to prevent electrical shock or electrocution.

4.DO NOT PULL THIS UNIT BY THE POWER CORD. Do not allow the power cord to come in contact with sharp instruments or edges, hot surfaces, or oil or grease. Do not place any weight on top of the power cord. A damaged power cord can cause electrical shock or electrocution.

5.SUPPORT THIS UNIT OR SECURELY CLAMP IT TO THE WORK SURFACE WHEN IT IS USED IN A PORTABLE APPLICATION to eliminate potential injury and/or damage from falling.

6.ENSURE THAT THE INTAKE AND EXHAUST AREAS ARE CLEAR PRIOR TO STARTING THE UNIT. Clogged intakes or exhausts can cause an explosion and/or fire.

7.DO NOT USE THE DUST COLLECTOR to pick up flammable liquids such as gasoline. Do not use the dust collector near flammable or combustible liquids. Explosion and/or fire can occur.

8.KEEP ARMS, HANDS, AND FINGERS AWAY FROM THE FAN. Avoid all exposure to rotating parts to prevent injury.

9.DO NOT OPERATE THIS UNIT WITHOUT THE DUST COLLECTION BAG IN PLACE AND PROPERLY SECURED. Sawdust and other debris can provide the potential for fire and/or explosion and can also cause inhalation problems.

10.INSPECT THE DUST BAG FOR CUTS, RIPS, OR TEARS. Replace damaged bags or vacuum hoses. Sawdust and other debris can provide the potential for fire and/or explosion and can also cause inhalation problems.

11.ALWAYS USE THE INTAKE CAPS TO COVER UNUSED DUST PORTS. Debris can cause damage to the unit and injury.

12.DO NOT ATTEMPT TO REMOVE OR REPLACE the dust collection bag(s) while the unit is connected to the power source. Exposed fan blades can cause severe injuries.

13.MAINTAIN THE UNIT IN TOP CONDITION. Clogged filters can increase the potential for fire or explosion. Follow all instructions for changing and cleaning filters.

14.STORE THIS UNIT IN A LOCATION that eliminates the potential for damage to the power cord. A damaged power cord can cause shock or electrocution. Safely store power cord on the unit to eliminate tripping hazards.

15.TURN THE UNIT “OFF” AND DISCONNECT THE UNIT from the power source before installing or removing accessories, before adjusting or changing set-ups, or when making repairs. An accidental start-up can cause serious injury.

16.TURN THE UNIT “OFF”, disconnect the unit from the power source, and clean the table/work area before leaving the area.

SAVE THESE INSTRUCTIONS.

Refer to them often

and use them to instruct others.

POWER CONNECTIONS

A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the machine. All line connections should make good contact. Running on low voltage will damage the machine.

Do not expose the machine to rain or operate the machine in damp locations.

MOTOR SPECIFICATIONS

Your machine is wired for 120, 60 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the “OFF” position.

GROUNDING INSTRUCTIONS

This machine must be grounded while in use to protect the operator from electric shock.

5

Image 5
Contents Contractors Saw Important Safety Instructions Table of ContentsCalifornia Proposition Safety Guidelines DefinitionsStay ALERT, Watch What YOU are DOING, and USE General Safety RulesPower Connections Additional Specific Safety RulesMotor Specifications Grounding InstructionsAll grounded, cord-connected machines Extension CordsFunctional Description Carton ContentsInstalling the Casters AssemblyInstalling the Exhaust Flange Assembly Tools RequiredDisconnect the machine from the power source Attaching the Vacuum Hose to the Dust Collector Locking the Switch in the OFF Position Operational Controls and AdjustmentsOperation Attaching the Dust BAG to the Dust CollectorTransportation and Storage TroubleshootingAccessories MaintenanceService Two Year Limited New Product Warranty WarrantyFrançais Mesures DE Sécurité Définitions LES Instructions Importantes DE SureteConservez CES Instructions LA Proposition DE CalifornieRègles DE Sécurité Générales Conserver CES Directives Règles DE Sécurité Spécifiques SupplémentairesRaccordements Électriques Spécifications DU MoteurMesur Minimum DE Corde D’EXTENSION Cordon DE RallongeContenus DE Boite Description FonctionnelleAVANT-PROPOS Désemballage ET Nettoyage’INSTALLATION DU Collier DE Serrage DE L’ÉVACUATION ’INSTALLATION DES RoulettesAssemblage Outils Nécessaires Pour L’ASSEMBLAGEDébrancher l’appareil de la source d’alimentation Assemblage DU Tuyau D’ASPIRATEUR AU Dépoussiéreur Assemblage DU SAC À Poussière AU Dépoussiéreur FonctionnementDémarrage ET Arrêt DE L’APPAREIL Verrouiller L’INTERRUPTEUR EN Position D’ARRÊTTransport ET Entreposage DepannageGarantie AccessoiriesEspañol Proposición DE California Instrucciones DE Seguridad ImportantesPautas DE SEGURIDAD/DEFINICIONES Normas Generales DE Seguridad Conexiones a LA Fuente DE Alimentación Normas Específicas Adicionales DE SeguridadEspecificaciones DEL Motor Instrucciones DE Conexión a TierraCordón DE Extensión DE Calibre Mínimo Cordones DE ExtensiónContenido DE Carton Descripción FuncionalPrologo Desempaquetado Y LimpiezaHerramientas DE Ensamblaje Requeridas EnsamblajeEstimación DEL Tiempo DE Ensamblaje Instalar LAS Ruedecillas¡Desconecte la Máquina de la Fuente del Poder DE UNA Manguera DE Aspiración EN EL Colector DE Polvo Fijación DEL Interruptor EN LA Posición DE Apagado OperaciónConectar DE LA Bolsa Para Polvo EN EL Colector DE Polvo Transporte Y Almacenamiento Localizacion DE FallasAccesorios ServicioGarantía limitada de dos años para productos nuevos GarantiaPlane , Whisper SERIES,WOODWORKER’S Choice