Elation Professional Spot 250 manual Lamp Optimization

Page 11

Design Spot 250™

2.Gently pull out the lamp/socket assembly to access the lamp.

3.Gently remove the old lamp by grasping it by the ceramic base.

4.Carefully insert the new lamp into the socket (Only use a MSD 250/2 GY9.5 lamp or equivalent). Please remember there is only one way to insert the lamp and the lamp should fit completely in the lamp socket.

5.Once the lamp has been inserted into the socket, gently slide the socket assembly back into place and secure with the two Phillips screws.

6.Always be sure to optimize the lamp after lamp replacement.

this device with open cover

Lamp Optimization

The lamp orientation and optimization must be adjusted after every lamp change. This procedure centers the lamp in the reflector. Proper optimization will increase lamp life and ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a lower deviation can cause damage to the lamp and/or lens.

The Design Spot 250™ lamp holder is aligned at the factory. However, due to slight imperfections in all lamps, fine adjustments will improve light performance. Please follow the procedure below for proper lamp optimization:

1.Using either a DMX controller or the control panel on the unit (see “SPOT” in the fixture menu on page 33), strike the lamp and focus the light on a flat surface (beam open, white, no gobo, no effect).

2.Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws labeled 1, 2, and 3 as illustrated on the next page. Turn one screw at a time to drag the hot-spot diagonally across the projected image. If you cannot detect a hot-spot, adjust the lamp until the light is even.

3.To reduce a hot-spot, pull the lamp in by turning all three screws clockwise a 1/4-turn

©Elation Professional®

11

Design Spot 250™

Image 11
Contents Design Spot Contents Support@elationlighting.com General InformationYourself, doing so will void your manufactures warranty Never open this fixture while in use Safety Instructions Design Spot Features General Guidelines Installation Procedure Lamp Installation InstructionsInstalling or replacing the lamp Lamp Optimization Design Spot Mounting Mounting and InstallationClamp Mounting Mounting pointsSecuring the Design Spot Understanding DMX DMX-512 connection with DMX terminator DMX-512 control connectionFixture DMX addressing Design Spot Display LED Indicators Fixture Menu Default settings shadedLamp OFF Test Menu Setting/Changing the DMX AddressMain Menu Functions Address MenuAuto Play Menu RUNAudi ALL Rese Reset MenuLamp Menu Gobo ScanColr Life ShtrOthr Time MenuRtlt Menu PleaseClear the lamp time every time you replace the lamp Rpan MenuDegr Menu Fine MenuDisplay Menu MIC MenuLaau Rdmx Fixture SettingsController Settings Spot Reset functionDlof DlayFans Reload the original factory settingsDfse FeedAdju VERREC Edit MenuSC01 StepDesign Spot RUN DMX Channel Traits Channel Rotating gobos, cont. rotation Channel 1 PAN movement 8bitChannel 9 3 facet rotating prism, Prism / Gobo macros Channel 7 Rotating Gobo Index, Rotating Gobo RotationChannel 8 Fixed Gobos Channel 13 Iris Channel 10 FocusChannel 11 Shutter, Strobe Control Channel 12 Dimmer IntensityChannel 16 Lamp on/off, Reset, Internal Programs Error Codes Design Spot Design Spot Disconnect from mains before starting maintenance operation Cleaning and MaintenanceYear Limited Warranty Design Spot Photometric Data Gobos Dimensional Drawings Circuit Schematic Power supply Power consumption Technical SpecificationsElation Professional