Design Spot 250™

(defective motor or a defective motor IC drive on the main PCB).

05Er - Color-wheel error:

The color wheel is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the color wheel’s magnetic- indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

06Er - Rotating gobo-wheel error:

The gobo-wheel is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the gobo wheel’s magnetic- indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

07Er - Rotating gobo indexing error:

The gobo is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

08Er - Fix Gobo-wheel error

This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB). The fix gobo wheel is not located in the default position after the reset.

09Er - Prism-wheel error

This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The Prism wheel is not located in the default position after the reset.

10Er - Focus-error

This message will appear after the reset of the fixture and if the magnetic indexing circuit

©Elation Professional®

46

Design Spot 250™

Image 46
Contents Design Spot Contents General Information Support@elationlighting.comYourself, doing so will void your manufactures warranty Never open this fixture while in use Safety Instructions Design Spot Features General Guidelines Installing or replacing the lamp Lamp Installation InstructionsInstallation Procedure Lamp Optimization Design Spot Mounting and Installation MountingMounting points Clamp MountingSecuring the Design Spot Understanding DMX DMX-512 control connection DMX-512 connection with DMX terminatorFixture DMX addressing Design Spot Display LED Indicators Default settings shaded Fixture MenuLamp OFF Address Menu Setting/Changing the DMX AddressMain Menu Functions Test MenuAudi Play Menu RUNAuto Lamp Menu Rese Reset MenuALL Colr ScanGobo Time Menu ShtrOthr LifeRpan Menu PleaseClear the lamp time every time you replace the lamp Rtlt MenuFine Menu Degr MenuMIC Menu Display MenuLaau Controller Settings Fixture SettingsRdmx Dlay Reset functionDlof SpotFeed Reload the original factory settingsDfse FansVER AdjuEdit Menu RECStep SC01Design Spot RUN DMX Channel Traits Channel 1 PAN movement 8bit Channel Rotating gobos, cont. rotationChannel 8 Fixed Gobos Channel 7 Rotating Gobo Index, Rotating Gobo RotationChannel 9 3 facet rotating prism, Prism / Gobo macros Channel 12 Dimmer Intensity Channel 10 FocusChannel 11 Shutter, Strobe Control Channel 13 IrisChannel 16 Lamp on/off, Reset, Internal Programs Error Codes Design Spot Design Spot Cleaning and Maintenance Disconnect from mains before starting maintenance operationYear Limited Warranty Design Spot Photometric Data Gobos Dimensional Drawings Circuit Schematic Technical Specifications Power supply Power consumptionElation Professional