Design Spot 250™
5.Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.
6.Press ENTER to confirm.
7.Press MODE/ESC to return to the main menu.
RDMX
– This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and the fixture. RDMX is on by default. Follow the procedure listed below to access the RDMX functions:
Fixture Settings:
1.Access the main menu.
2.Tap the UP button until “SPEC” is displayed, press ENTER.
3.Tap the UP button until “RDMX” is displayed, press ENTER.
4.The display will show “ON/OFF.”
5.Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function.
6.Press ENTER to confirm.
7.Press MODE/ESC to return to the main menu.
Controller Settings:
1.Set the DMX value of channel 1 to a value of 7.
2.Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7" you can adjust the starting address between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511.
3.Use channel 3 to set your desired DMX starting address. For example: If you want to set the starting address to 57, set channel 1 to a value of “7,” set channel 2 to a value of “7” and use channel 3 to set your address to 57 by selecting a channel value of 57. Example 2: If you want to set the starting address to 420, set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420).
4.Wait for approximately 20 seconds for the unit to complete the address
©Elation Professional® | 32 | Design Spot 250™ |