Design Spot 250™

11. ERROR CODES:

When power is applied, the unit will automatically enter a “reset/test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will flash in the display in the form of “XXer” were as XX will represent a function number. For example, when the display shows “02Er,” it means there is some type of error with the channel 2 motor. If there are multiple errors during the start-up process they will all flash in the display. For example: if the fixtures has errors on channel 1, channel 2, and channel 5 all at the same time, you will see the error message “01Er”, “02Er,” and ”05Er” flash repeated 5 times.

If an error does occur during the initial start-up procedure the fixture will self-generate a second reset signal and try to realign all the motors and correct the errors, if the error persist after a second attempt a third attempt will be made.

If after a third attempt all the errors have not been corrected the fixture will make the following determinations: 1) 3 or more errors - The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand-by mode until subsequent repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore most other functions will work properly. The fixture will attempt to operate normally until the errors can be correct by a technician. The errors in question will remain flashing in the display as a reminder of internal errors.

01Er – PAN movement error:

The yoke is not located in the default position after start-up or after a reset command. This message will appear after a fixture reset if the pan-yoke’s magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).

03Er – TILT movement error:

The head is not located in the default tilt position after start-up or after a reset command. This message will appear after a fixture reset if the tilt magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure

©Elation Professional®

45

Design Spot 250™

Image 45
Contents Design Spot Contents Support@elationlighting.com General InformationYourself, doing so will void your manufactures warranty Never open this fixture while in use Safety Instructions Design Spot Features General Guidelines Lamp Installation Instructions Installing or replacing the lampInstallation Procedure Lamp Optimization Design Spot Mounting Mounting and InstallationClamp Mounting Mounting pointsSecuring the Design Spot Understanding DMX DMX-512 connection with DMX terminator DMX-512 control connectionFixture DMX addressing Design Spot Display LED Indicators Fixture Menu Default settings shadedLamp OFF Main Menu Functions Setting/Changing the DMX AddressAddress Menu Test MenuPlay Menu RUN AudiAuto Rese Reset Menu Lamp MenuALL Scan ColrGobo Othr ShtrTime Menu LifeClear the lamp time every time you replace the lamp PleaseRpan Menu Rtlt MenuDegr Menu Fine MenuDisplay Menu MIC MenuLaau Fixture Settings Controller SettingsRdmx Dlof Reset functionDlay SpotDfse Reload the original factory settingsFeed FansAdju VERREC Edit MenuSC01 StepDesign Spot RUN DMX Channel Traits Channel Rotating gobos, cont. rotation Channel 1 PAN movement 8bitChannel 7 Rotating Gobo Index, Rotating Gobo Rotation Channel 8 Fixed GobosChannel 9 3 facet rotating prism, Prism / Gobo macros Channel 11 Shutter, Strobe Control Channel 10 FocusChannel 12 Dimmer Intensity Channel 13 IrisChannel 16 Lamp on/off, Reset, Internal Programs Error Codes Design Spot Design Spot Disconnect from mains before starting maintenance operation Cleaning and MaintenanceYear Limited Warranty Design Spot Photometric Data Gobos Dimensional Drawings Circuit Schematic Power supply Power consumption Technical SpecificationsElation Professional