York YR manual Solid State Starter Only Lcsss

Page 12

OptiView Control Center (continued)

FORM 160.81-EG1

Low Discharge Superheat Detected

Maximum Load – Load Limit

Minimum Load – Load Limit

Oil – Dirty Filter

Oil – High Temperature

Slide Valve Uncalibrated

Routine Shutdown Messages Include:

Remote Stop

Local Stop

Place Compressor Switch In Run Position

Cycling Shutdown Messages Include:

Multiunit Cycling – Contacts Open

System Cycling – Contacts Open

Control Panel – Power Failure

Leaving Chilled Liquid – Low Temperature

Leaving Chilled Liquid – Flow Switch Open

Condenser – Flow Switch Open

Motor Controller – Contacts Open

Motor Controller – Loss of Current

Power Fault

Control Panel – Schedule

Solid State Starter Only (LCSSS)

Initialization Failed

Serial Communications

Requesting Fault Data

Stop Contacts Open

Power Fault

Low Phase (X) Temperature Sensor

Run Signal

Invalid Current Scale Selection

Phase Locked Loop

Low Supply Line Voltage

High Supply Line Voltage

Logic Board Processor

Logic Board Power Supply

Phase Loss

Safety Shutdown Messages include:

Evaporator – Low Pressure

Evaporator – Low Pressure – Smart Freeze

Evaporator – Transducer or Leaving Liquid Probe

Evaporator – Transducer or Temperature Sensor

Condenser – High Pressure Contacts Open

Condenser – High Pressure

Condenser – Pressure Transducer Out of Range

Auxiliary Safety – Contacts Closed

Discharge – High Temperature

Discharge – Low Temperature

Oil – Low Differential Pressure

Oil or Condenser Transducer Error

Oil – Clogged Filter

Oil – High Pressure

Control Panel – Power Failure

Watchdog – Software Reboot

Solid State Starter Only (LCSSS)

Shutdown – Requesting Fault Data . . .

High Instantaneous Current

High Phase (X) Heatsink Temperature – Running

105% Motor Current Overload

Motor or Starter – Current Imbalance

Open SCR

Phase Rotation

12

YORK INTERNATIONAL

 

Image 12
Contents Ashrae 90.1Compliant Table of Contents Introduction Ratings ARI Certification ProgramComputerized Performance Ratings OFF-DESIGN PerformanceOptiView Control Center Optiview Control CenterDisplay Only Programmable On Setpoint Off Setpoint Set Date Set Time Clock Enabled/Disabled 12/24 Hour Time Remaining Until Next Print Display Messages Solid State Starter Only Lcsss Mechanical Specifications Mechanical Specifications Form 160.81-EG1 Refrigerant SystemGeneral Control PanelYork International Startup and Operator Training Codes and StandardsIsolation Mounting Refrigerant ContainmentAccessories and Modifications SI Metric Conversion Marine Water BoxesKNOCK-DOWN Shipment Refrigerant STORAGE/RECYCLING SystemApplication Data LocationWater Circuits Multiple Units Parallel Evaporators Parallel CondensersSound and Vibration Considerations Brine ApplicationsRefrigerant Relief Piping Thermal InsulationElectrical Considerations Ampacity on Line Side of StarterMotor Electrical Data FLA = 50 HZ Electrical Data Motor END Compressor Dimensions TOP ViewWater BOX Dimensions FT. DIM Evaporators T Condenser T Pass Dimensions Ft.-In. Nozzle Arrangements Evaporators Compact Water BoxesDimensions mm Nozzle Arrangements Evaporators Compact Water BoxesCondensers Compact Water Boxes Passes Dimensions In. Floor Layout Neoprene IsolatorsDimensions mm Floor Layout Dimensions Floor Layout Spring IsolatorsWeights Unit WeightsSolid State Starter Weight Guide Specifications CompressorLubrication System Motor EvaporatorCondenser Refrigerant SystemOptiview Control Center Compressor Motor Starter OPTION, 200 Portable Refrigerant STORAGE/RECY- Cling System START-UP and Operator Training