York YR manual Dimensions, TOP View

Page 26

FORM 160.81-EG1

Dimensions

MOTOR M

END

8-1/2"

(216 mm)

RELIEF VALVES (SEE TABLE)

MOTOR COMPRESSOR

COMPRESSOR

END

RELIEF VALVE (SEE TABLE)

ISOLATION VALVE

NOTE: OPTIONAL

TOP VIEW

RELIEF VALVES*

LOCATION

WITH ISOLATION

WITHOUT ISOLATION

VALVES

VALVES

 

EVAPORATOR

1" SINGLE

1" DUAL

CONDENSER

1" DUAL

1" SINGLE

DISCHARGE

1-1/4" SINGLE

NONE

LINE

 

 

*All are NPT female

 

 

 

SOLID STATE STARTER

 

ISOLATION VALVE

 

(OPTIONAL)

 

 

OIL SEPARATOR

NOTE: OPTIONAL

 

OPTIVIEW

 

 

MOTOR

CONTROL PANEL

COMPRESSOR

RELIEF VALVE

 

END

 

END

NOTE: ONLY SUPPLIED

 

ON UNITS WITH

 

2' - 3-1/2"

 

L

 

OPTIONAL ISOLATION

(698 mm)

 

VALVES

 

 

2' - 6-1/4"

 

 

 

(768 mm)

 

B

 

 

 

 

 

 

U

 

B

 

P

 

C

 

 

 

3'-8-3/4 "

 

CONDENSER

EVAPORATOR

(1136.7 mm)

 

 

 

F

G

 

 

D

E

K

A

J

C

 

H

FRONT OF UNIT

 

LD07981

SECTION A - A

 

FIG. 3 – T0 & T3 COMPRESSORS – EVAPORATOR, CONDENSER AND WATER BOXES DIMENSIONS

26

YORK INTERNATIONAL

 

Image 26
Contents Compliant Ashrae90.1 Table of Contents Introduction Computerized Performance Ratings RatingsARI Certification Program OFF-DESIGN PerformanceOptiView Control Center Optiview Control CenterDisplay Only Programmable On Setpoint Off Setpoint Set Date Set Time Clock Enabled/Disabled 12/24 Hour Time Remaining Until Next Print Display Messages Solid State Starter Only Lcsss Mechanical Specifications General Mechanical Specifications Form 160.81-EG1Refrigerant System Control PanelYork International Isolation Mounting Startup and Operator TrainingCodes and Standards Refrigerant ContainmentAccessories and Modifications KNOCK-DOWN Shipment SI Metric ConversionMarine Water Boxes Refrigerant STORAGE/RECYCLING SystemWater Circuits Application DataLocation Multiple Units Parallel Evaporators Parallel CondensersRefrigerant Relief Piping Sound and Vibration ConsiderationsBrine Applications Thermal InsulationMotor Electrical Data Electrical ConsiderationsAmpacity on Line Side of Starter FLA = 50 HZ Electrical Data Motor END Compressor Dimensions TOP ViewWater BOX Dimensions FT. DIM Evaporators T Condenser T Pass Dimensions Ft.-In. Nozzle Arrangements Evaporators Compact Water BoxesDimensions mm Nozzle Arrangements Evaporators Compact Water BoxesCondensers Compact Water Boxes Passes Dimensions In. Floor Layout Neoprene IsolatorsDimensions mm Floor Layout Dimensions Floor Layout Spring IsolatorsSolid State Starter Weight WeightsUnit Weights Lubrication System Guide SpecificationsCompressor Condenser MotorEvaporator Refrigerant SystemOptiview Control Center Compressor Motor Starter OPTION, 200 Portable Refrigerant STORAGE/RECY- Cling System START-UP and Operator Training