TROUBLESHOOTING & REPAIR |
| |||||
|
|
| ||||
Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |||
detailed in the beginning of this manual. |
|
|
|
| ||
|
|
|
|
| ||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
Major physical or electrical dam- | 1. | Contact the Lincoln Electric |
|
|
| |
age is evident. |
|
| Service Dept. |
|
|
|
|
|
|
| |||
The machine is dead - the input | 1. | The power switch (S1) is in the | 1. Check the power switch (S1) | |||
contactor does not operate. The |
| ON position. | and associated leads and con- | |||
pilot light is not lit. |
| 2. | Check for blown or missing | nections. | See the | Wiring |
|
| Diagram. |
|
| ||
|
|
| fuses in the input lines. |
|
| |
|
|
|
|
|
| |
|
| 3. | Check the | 2. Perform the | Control | Trans- |
|
| former Test. |
|
| ||
|
|
| line voltage at the machine. |
|
| |
|
|
|
|
|
| |
|
|
| The input voltage must match |
|
|
|
|
|
| the rating plate and reconnect |
|
|
|
|
|
| panel. |
|
|
|
|
|
|
| |||
The input contactor operates, but | 1. | Check the electrode and work | 1. Perform the Internal Trigger | |||
no welding output. | The 115 VAC |
| cables for loose or faulty con- | Circuit Test. |
|
|
auxiliary supply is | present at the |
| nections. | 2. Perform the Firing Board Test. | ||
receptacle. |
|
|
| |||
| 2. If the Thermal Protection Light |
|
|
| ||
|
| 3. Perform the Main Transformer | ||||
|
|
| is ON, the machine is overheat- | |||
|
|
| Test. |
|
| |
|
|
| ed. Wait for the machine to |
|
| |
|
|
|
|
|
| |
|
|
| cool and remedy the cause of | 4. Perform the SCR Output | ||
|
|
| the overheating problem. See | Bridge Test. |
|
|
|
|
| the Fan/Snubber Board LED | 5. The control | board may be | |
|
|
| Chart. | |||
|
|
| faulty. See Control Board LED | |||
|
|
|
| |||
|
| 3. | Make certain either the output | Chart. |
|
|
|
|
| terminals switch is in the ON |
|
|
|
|
|
| position or the external gun |
|
|
|
|
|
| trigger circuit is functioning |
|
|
|
|
|
| properly. |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call