TROUBLESHOOTING & REPAIR

INPUT CONTACTOR TEST (continued)

FIGURE F.13 – INPUT CONTACTOR TEST CONNECTIONS

X1, #256

#256

#255A

#255A

Return to Section TOC

Return to Master TOC

TEST FOR CONTACT CONTINUITY

1.Disconnect the main input supply power to the DC-655 machine.

2.Locate, label and remove the three leads connected to the input contactor coil (X1/#256 and #255A). See Figure F.13.

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically hot parts.

3.Using the external 120 VAC supply, apply 120 VAC to the terminals of the input con- tactor coil. If the contactor does NOT acti- vate, the input contactor is faulty.

4.With the contactor activated, check the continuity across the contacts. (Zero ohms or very low resistance is normal.) See Figure F.13. If the resistance is high, the input contactor is faulty. Replace the input contactor.

5.When the contactor is NOT activated, the resistance should be infinite or very high across the contacts. If the resistance is low, the input contactor is faulty. Replace the input contactor.

Return to Section TOC

Return to Master TOC

IDEALARC DC-655

Image 76
Contents Idealarc DC-655 Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Installation Technical Specifications DC-655Input Power Three Phase Select Suitable Location Safety PrecautionsElectrical Input Connections Input Power Supply Connections Input Supply Connection DiagramOutput Connections Electrode and Work CablesAuxiliary Power Control Connections Auxiliary Power TableTerminal Strip 1 T.S.1 Terminal Strip 2 T.S.2Table of Contents Operation Section OPERATIONB-2 Operating InstructionsDesign Features Advantages OperationGeneral Description Recommended Processes and EquipmentDC-655 Figure B.2 Lower Case Front Controls & Connections Machine Protection Auxiliary PowerCase Back Connections Thermal Shutdown Remote Control Leads Fault Protection SHUTDOWN1Over Current Protection Shutdown CV Mode CURRENT-LIMITING CC Mode HOT StartCC Mode ARC Force CC Mode ARC Gouging Welding PerformanceTable of Contents Accessories Field Installed Options Remote Output ControlAutomatic Wire Feeders SEMI-AUTOMATIC Wire FeedersSet the Idealarc DC-655 Power toggle Accessories Semiautomatic Wire Feeders Connecting the LN-7 to the Idealarc DC-655 Terminal Strip GND Negative Positive Figure C.4 Idealarc DC-655 Table of Contents Maintenance General Maintenance Electric Shock can killFigure D.1 General Component Locations Idealarc DC-655 Table of Contents Theory of Operation Section Theory of Operation Down Circuits Protective Devices and Shutdown Circuits SCR Operation Figure E.4 SCR OperationIdealarc DC-655 Table of Contents Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Troubleshooting Guide Board LED Chart ControlLED Chart OutputBridge Test Perform the SCR Bridge TestMain See the Idle Shut Down TimerTransformer Test Function Problems Thermal Fan/Snubber PC Troubleshooting & Repair Welding Problems Mode Current Limiting See the Control BoardTest Description Internal Trigger Circuit TestMaterials Needed Trigger Diagram Test ProcedureInternal Trigger Circuit Test Simplified Trigger Diagram. If a resistance SectionFigure F.3 Simplified Trigger Diagram Firing Board Test Firing Board Test Figure F.4 Firing Board Trigger Circuit Test Points and LEDsMain Transformer Test Figure F.5 14-PIN Receptacle Figure F.4 Main Transformer T1 Voltage Test Main Transformer T1 Voltage Test Figure F.6 Input Contactor and Primary LeadsTroubleshooting & Repair Figure F.8 Terminal Strip Figure F.9 Firing Board Plug J5 Pins Control Transformer T2 Test Control Transformer T2 Test Figure F.10 Control TransformerHigh Voltage is present at Control Board Transformer T3 Test Control Board Transformer T3 Test Perform the Control Transformer T2 TestInput Contactor Test Input Contactor Test Transformer T2 TestTest for Contact Continuity Figure F.13 Input Contactor Test ConnectionsStatic SCR Test Static SCR Test Figure F.15 Heat Sink Test Points Active SCR Test Active SCR Test Figure F.17 Heat Sink Test Points Anode Cathode Thermal FAN/SNUBBER Board LED Chart LED Functions and IndicationsControl Board LED Chart LED # LED Functions and IndicationsScope Settings Maximum Output Setting no Load Normal Open Circuit Voltage Waveform Constant Voltage MIGMinimum Output Setting no Load Troubleshooting & Repair Typical SCR Gate Voltage Waveform Constant Voltage MIG Installation Input Contactor CR1 CLEANING/REPLACEMENT DescriptionInput Contactor CR1 CLEANING/REPLACEMENT Cleaning ProcedureSCR Rectifier Bridge Removal Replacement Procedure Procedure Replacement ProcedureSCR Rectifier Bridge Removal Reassembly SCR Rectifier Bridge LEG Assembly Mounting BracketsMain Transformer and Choke Removal Replacement Procedure Main Transformer and Choke Removal Output Choke RemovalMain Transformer Removal Retest After Repair Input Idle Amps and WattsSVM Error Reporting Form Section G Electrical Diagrams Control Board Schematic G3384 Firing Board Schematic G2792 Thermal Fan/Snubber Board Schematic L10123 Control Board Layout G3385-1 Firing Board Layout G2699-2 Thermal Fan/Snubber Board Layout L10124-1 Return to Section TOC