| TROUBLESHOOTING & REPAIR | ||
|
| THERMAL FAN/SNUBBER BOARD LED CHART | |||
|
|
|
|
|
|
|
| LED # |
| LED FUNCTIONS AND INDICATIONS |
|
|
|
|
| (Machine is ON) |
|
|
|
|
|
| |
| 1 |
| Indicates fan should be running. |
| |
|
|
|
|
| |
| 2 |
| Indicates welding current is greater than 200 amps. |
| |
|
|
|
|
| |
| 3 |
| Indicates fan should be running due to heating of main |
| |
|
|
|
| SCRs. |
|
|
|
|
|
| |
| 4 |
| Indicates an open thermal fan thermistor or an open con- |
| |
|
|
|
| nection between the thermistor and the thermal fan/snub- |
|
|
|
|
| ber board. See the Wiring Diagram (leads #319 and |
|
|
|
|
| #316). |
|
|
|
|
|
| |
| 5 |
| Indicates a thermostat (choke or secondary) has opened. |
| |
|
|
|
| The thermal protection light should also be illuminated. |
|
|
|
|
|
| |
| 6 |
| Indicates the fan motor should be running. LED 6 should |
| |
|
|
|
| be illuminated and the fan running when any |
|
|
|
|
| of the following LEDs are lit: LED 2, LED 3, LED 4, or |
|
|
|
|
| LED 5. |
|
|
|
|
|
|
|