| TROUBLESHOOTING & REPAIR |
|
| Observe Safety Guidelines | TROUBLESHOOTING GUIDE |
detailed in the beginning of this manual.
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
The 115 VAC receptacle is not | 1. The circuit breaker may be | 1. The circuit breaker may be | |||
working. The machine’s welding | tripped. Reset if necessary. | defective. Check | associated | ||
output is normal. | 2. Make sure the 115 VAC plug | wiring. See the Wiring Diagram. | |||
|
|
|
|
| |
| and “load” is in good working | 2. Check for 115 VAC at terminals | |||
| condition. | #31 and #32 on the terminal | |||
|
| strip. If 115 VAC is present at | |||
|
| the terminal strip, check the | |||
|
| wiring | between the | terminal | |
|
| stirp, the circuit breaker and the | |||
|
| 115 VAC receptacle. If 115 VAC | |||
|
| is NOT present at the terminal | |||
|
| strip, | perform | the | Main |
|
| Transformer Test. |
|
| |
|
| 3. The 115 VAC receptacle may | |||
|
| be defective. |
|
| |
|
|
|
|
|
|
When not welding for a period of | 1. This may be a normal condition. |
|
|
|
|
time, the machine shuts down. | See the Idle Shut Down Timer. |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call