Lincoln Electric DC-655 service manual Main, Transformer Test, See the Idle Shut Down Timer

Page 49

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

F-7

 

 

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

The 115 VAC receptacle is not

1. The circuit breaker may be

1. The circuit breaker may be

working. The machine’s welding

tripped. Reset if necessary.

defective. Check

associated

output is normal.

2. Make sure the 115 VAC plug

wiring. See the Wiring Diagram.

 

 

 

 

 

 

and “load” is in good working

2. Check for 115 VAC at terminals

 

condition.

#31 and #32 on the terminal

 

 

strip. If 115 VAC is present at

 

 

the terminal strip, check the

 

 

wiring

between the

terminal

 

 

stirp, the circuit breaker and the

 

 

115 VAC receptacle. If 115 VAC

 

 

is NOT present at the terminal

 

 

strip,

perform

the

Main

 

 

Transformer Test.

 

 

 

 

3. The 115 VAC receptacle may

 

 

be defective.

 

 

 

 

 

 

 

 

When not welding for a period of

1. This may be a normal condition.

 

 

 

 

time, the machine shuts down.

See the Idle Shut Down Timer.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

IDEALARC DC-655

Image 49
Contents Idealarc DC-655 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications DC-655 InstallationInput Power Three Phase Select Suitable Location Safety PrecautionsElectrical Input Connections Input Supply Connection Diagram Input Power Supply ConnectionsElectrode and Work Cables Output ConnectionsAuxiliary Power Table Auxiliary Power Control ConnectionsTerminal Strip 2 T.S.2 Terminal Strip 1 T.S.1Table of Contents Operation Section Operating Instructions OPERATIONB-2Operation Design Features AdvantagesGeneral Description Recommended Processes and EquipmentDC-655 Figure B.2 Lower Case Front Controls & Connections Machine Protection Auxiliary PowerCase Back Connections Thermal Shutdown Remote Control Leads Fault Protection SHUTDOWN1Over Current Protection Shutdown CC Mode HOT Start CV Mode CURRENT-LIMITINGCC Mode ARC Force CC Mode ARC Gouging Welding PerformanceTable of Contents Accessories Remote Output Control Field Installed OptionsSEMI-AUTOMATIC Wire Feeders Automatic Wire FeedersSet the Idealarc DC-655 Power toggle Accessories Semiautomatic Wire Feeders Connecting the LN-7 to the Idealarc DC-655 Terminal Strip GND Negative Positive Figure C.4 Idealarc DC-655 Table of Contents Maintenance Electric Shock can kill General MaintenanceFigure D.1 General Component Locations Idealarc DC-655 Table of Contents Theory of Operation Section Theory of Operation Down Circuits Protective Devices and Shutdown Circuits Figure E.4 SCR Operation SCR OperationIdealarc DC-655 Table of Contents Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairPC Board Troubleshooting Procedures Troubleshooting Guide Control Board LED ChartOutput LED ChartBridge Test Perform the SCR Bridge TestMain See the Idle Shut Down TimerTransformer Test Function Problems Thermal Fan/Snubber PC Troubleshooting & Repair Welding Problems See the Control Board Mode Current LimitingTest Description Internal Trigger Circuit TestMaterials Needed Trigger Diagram Test ProcedureInternal Trigger Circuit Test Section Simplified Trigger Diagram. If a resistanceFigure F.3 Simplified Trigger Diagram Firing Board Test Figure F.4 Firing Board Trigger Circuit Test Points and LEDs Firing Board TestMain Transformer Test Figure F.5 14-PIN Receptacle Figure F.4 Main Transformer T1 Voltage Test Figure F.6 Input Contactor and Primary Leads Main Transformer T1 Voltage TestTroubleshooting & Repair Figure F.8 Terminal Strip Figure F.9 Firing Board Plug J5 Pins Control Transformer T2 Test Figure F.10 Control Transformer Control Transformer T2 TestHigh Voltage is present at Control Board Transformer T3 Test Perform the Control Transformer T2 Test Control Board Transformer T3 TestInput Contactor Test Transformer T2 Test Input Contactor TestFigure F.13 Input Contactor Test Connections Test for Contact ContinuityStatic SCR Test Static SCR Test Figure F.15 Heat Sink Test Points Active SCR Test Active SCR Test Figure F.17 Heat Sink Test Points Anode Cathode LED Functions and Indications Thermal FAN/SNUBBER Board LED ChartLED # LED Functions and Indications Control Board LED ChartScope Settings Normal Open Circuit Voltage Waveform Constant Voltage MIG Maximum Output Setting no LoadMinimum Output Setting no Load Troubleshooting & Repair Typical SCR Gate Voltage Waveform Constant Voltage MIG Installation Description Input Contactor CR1 CLEANING/REPLACEMENTCleaning Procedure Input Contactor CR1 CLEANING/REPLACEMENTSCR Rectifier Bridge Removal Replacement Procedure Procedure Replacement ProcedureSCR Rectifier Bridge Removal SCR Rectifier Bridge LEG Assembly Mounting Brackets ReassemblyMain Transformer and Choke Removal Replacement Procedure Output Choke Removal Main Transformer and Choke RemovalMain Transformer Removal Input Idle Amps and Watts Retest After RepairSVM Error Reporting Form Section G Electrical Diagrams Control Board Schematic G3384 Firing Board Schematic G2792 Thermal Fan/Snubber Board Schematic L10123 Control Board Layout G3385-1 Firing Board Layout G2699-2 Thermal Fan/Snubber Board Layout L10124-1 Return to Section TOC
Related manuals
Manual 4 pages 58.8 Kb