Lincoln Electric DC-655 service manual Retest After Repair, Input Idle Amps and Watts

Page 99

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-57

F-57

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.

INPUT IDLE AMPS AND WATTS

Input volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

208/3/60

11.0

1.0

230/3/60

10.0

1.0

380/3/60

6.0

1.0

416/3/60

5.5

1.0

460/3/60

5.0

1.0

550/3/60

4.2.

1.0

575/3/60

4.0

1.0

200/3/50

21.0

1.3

220/3/50

19.1

1.3

230/3/50

18.3

1.3

380/3/50

11.0

1.3

400/3/50

10.5

1.3

415/3/50

10.1

1.3

440/3/50

9.6

1.3

500/3/50

8.4

1.3

550/3/50

7.7

1.3

 

 

 

MAXIMUM OPEN CIRCUIT VOLTAGES

 

Mode

Input Hertz

Open Circuit Volts

 

CC Stick

60

66/70

 

CV MIG

60

44/47

 

Auxiliary Output (#31-#32)

60

122/128 VAC

 

Auxiliary Output (#41-#42)

60

44/48 VAC

 

 

 

 

MINIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MAXIMUM OUTPUT SETTINGS

Mode

Control Settings

Load

CC Stick

Output Control at Maximum

815 Amps @ 44.0 Volts (Min)

 

Arc Force Control at

 

 

Minimum

 

CV MIG

Output Control at Maximum

815 Amps @ 44.0 Volts (Min)

Auxiliary Output (#31-#32)

N/A

5 Amps @ 120/126 VAC (Min)

Auxiliary Output (#41-#42)

N/A

5 Amps #41/45 VAC (Min)

 

 

 

IDEALARC DC-655

Image 99
Contents Idealarc DC-655 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications DC-655 InstallationInput Power Three Phase Safety Precautions Select Suitable LocationElectrical Input Connections Input Supply Connection Diagram Input Power Supply ConnectionsElectrode and Work Cables Output ConnectionsAuxiliary Power Table Auxiliary Power Control ConnectionsTerminal Strip 2 T.S.2 Terminal Strip 1 T.S.1Table of Contents Operation Section Operating Instructions OPERATIONB-2Recommended Processes and Equipment Design Features AdvantagesOperation General DescriptionDC-655 Figure B.2 Lower Case Front Controls & Connections Auxiliary Power Machine ProtectionCase Back Connections Remote Control Leads Fault Protection SHUTDOWN1 Thermal ShutdownOver Current Protection Shutdown Welding Performance CV Mode CURRENT-LIMITINGCC Mode HOT Start CC Mode ARC Force CC Mode ARC GougingTable of Contents Accessories Remote Output Control Field Installed OptionsSEMI-AUTOMATIC Wire Feeders Automatic Wire FeedersSet the Idealarc DC-655 Power toggle Accessories Semiautomatic Wire Feeders Connecting the LN-7 to the Idealarc DC-655 Terminal Strip GND Negative Positive Figure C.4 Idealarc DC-655 Table of Contents Maintenance Electric Shock can kill General MaintenanceFigure D.1 General Component Locations Idealarc DC-655 Table of Contents Theory of Operation Section Theory of Operation Down Circuits Protective Devices and Shutdown Circuits Figure E.4 SCR Operation SCR OperationIdealarc DC-655 Table of Contents Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairPC Board Troubleshooting Procedures Troubleshooting Guide Control Board LED ChartPerform the SCR Bridge Test LED ChartOutput Bridge TestSee the Idle Shut Down Timer MainTransformer Test Function Problems Thermal Fan/Snubber PC Troubleshooting & Repair Welding Problems See the Control Board Mode Current LimitingInternal Trigger Circuit Test Test DescriptionMaterials Needed Test Procedure Trigger DiagramInternal Trigger Circuit Test Section Simplified Trigger Diagram. If a resistanceFigure F.3 Simplified Trigger Diagram Firing Board Test Figure F.4 Firing Board Trigger Circuit Test Points and LEDs Firing Board TestMain Transformer Test Figure F.5 14-PIN Receptacle Figure F.4 Main Transformer T1 Voltage Test Figure F.6 Input Contactor and Primary Leads Main Transformer T1 Voltage TestTroubleshooting & Repair Figure F.8 Terminal Strip Figure F.9 Firing Board Plug J5 Pins Control Transformer T2 Test Figure F.10 Control Transformer Control Transformer T2 TestHigh Voltage is present at Control Board Transformer T3 Test Perform the Control Transformer T2 Test Control Board Transformer T3 TestInput Contactor Test Transformer T2 Test Input Contactor TestFigure F.13 Input Contactor Test Connections Test for Contact ContinuityStatic SCR Test Static SCR Test Figure F.15 Heat Sink Test Points Active SCR Test Active SCR Test Figure F.17 Heat Sink Test Points Anode Cathode LED Functions and Indications Thermal FAN/SNUBBER Board LED ChartLED # LED Functions and Indications Control Board LED ChartScope Settings Normal Open Circuit Voltage Waveform Constant Voltage MIG Maximum Output Setting no LoadMinimum Output Setting no Load Troubleshooting & Repair Typical SCR Gate Voltage Waveform Constant Voltage MIG Installation Description Input Contactor CR1 CLEANING/REPLACEMENTCleaning Procedure Input Contactor CR1 CLEANING/REPLACEMENTSCR Rectifier Bridge Removal Replacement Procedure Replacement Procedure ProcedureSCR Rectifier Bridge Removal SCR Rectifier Bridge LEG Assembly Mounting Brackets Reassembly Main Transformer and Choke Removal Replacement Procedure Output Choke Removal Main Transformer and Choke RemovalMain Transformer Removal Input Idle Amps and Watts Retest After RepairSVM Error Reporting Form Section G Electrical Diagrams Control Board Schematic G3384 Firing Board Schematic G2792 Thermal Fan/Snubber Board Schematic L10123 Control Board Layout G3385-1 Firing Board Layout G2699-2 Thermal Fan/Snubber Board Layout L10124-1 Return to Section TOC