Emerson 1F92 manual FAN Operation, Heating System, Until FAN Auto

Page 22

DISABLING AUTOMATIC

CHECK THERMOSTAT OPERATION

CHANGEOVER MODE.

(Installer table step 13). This thermostat, as configured at the factory, provides automatic changeover, which allows the thermostat to switch between heating and cooling to maintain temperature. In this configuration, when you press the SYSTEM button, the thermostat will go through HEAT-OFF-COOL-AUTO modes (HEAT-EMER-OFF-COOL- AUTO for heat pumps). Select HEAT(-EMER)-OFF-COOL to disable the automatic changeover feature.

FAN OPERATION

If your system does not have a G terminal connection, skip to “Heating System” section.

1.Turn power on to the system.

2.Press PROGRAM RUN .

3.

Press

FAN

until FAN ON is

 

displayed. The fan should begin

 

to operate.

 

4.

Press

FAN

until FAN AUTO

 

is displayed. The fan should stop

 

operating.

 

HEATING SYSTEM

1.Press PROGRAM RUN .

2.Press SYSTEM until HEAT is

displayed. If the heating system has a standing pilot, ensure that it is lit.

3.Press to adjust thermostat setting above room temperature. The heating system should begin to operate.

4.Press to adjust tempera- ture below room temperature. The heating system should stop operating.

20

Image 22
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Electrical Data InstallationSpecifications Thermal DataPrecautions Remove OLD Thermostat InstallationAttach Base to Wall Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusElectric Heat FAN Configuration MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Programmable Heat FAN-OFF Delay Programmable Cool FAN-OFF and FAN-ON DelayPump Fossil Fuel KIT Alternative Economizer Feature Compressor LockoutHeating System FAN OperationUntil FAN Auto Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Entering Your Program To Set the Clock ProgrammingProgrammed Operation Planning Your Program To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Adjustable Temperature Display FeaturesSelectable Energy Management Recovery EMR Heat Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Cool FastActivate RUN PRG by Telephone Compressor Run Time Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonLarge Lighted Liquid Crystal Display LCD Thermostat Startup After Total Power LossArm Chair Programming Second Stage Time Delay Features IndexPage Page Part no -6422C