SPECIFICATIONS

1F92-371:

Standard Systems:

Operating Ambient Temperature:

5/2 Day programming; residential applications

ELECTRICAL DATA

Electrical Rating:

20 to 30 VAC, 50/60 Hz with common

0.05 to 1.5 Amps per terminal

2.5Amps maximum total load (all terminals combined)

Multi-stage gas, oil, electric.

Single-stage or two-stage compres- sor heat pump.

THERMAL DATA

Setpoint Temperature Range:

45° to 99°F (7° to 37°C)

32° to 110°F (0° to 43°C)

Operating Humidity Range:

90% non-condensing max.

Shipping Temperature Range:

-4° to 149°F (-20° to 65°C)

4

Image 6
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Electrical Data InstallationSpecifications Thermal DataPrecautions Installation Remove OLD ThermostatAttach Base to Wall Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusElectric Heat FAN Configuration MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Programmable Cool FAN-OFF and FAN-ON Delay Programmable Heat FAN-OFF DelayPump Fossil Fuel KIT Alternative Economizer Feature Compressor LockoutFAN Operation Heating SystemUntil FAN Auto Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Entering Your Program To Set the Clock ProgrammingProgrammed Operation Planning Your Program To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Features Adjustable Temperature DisplaySelectable Energy Management Recovery EMR Heat Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Cool FastActivate RUN PRG by Telephone Compressor Run Time Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonThermostat Startup After Total Power Loss Large Lighted Liquid Crystal Display LCDArm Chair Programming Second Stage Time Delay Features IndexPage Page Part no -6422C