Emerson 1F92 manual Orientation, Thermostat Buttons

Page 4

ORIENTATION

THE THERMOSTAT BUTTONS

See inside front cover for illustration showing button locations.

1(Blue arrow) Lowers temperature setting (45°F or 7°C minimum)

2(Red arrow) Raises temperature setting (99°F or 37°C maximum)

3The multi-color indicator glows: green for 1st stage, yellow for 2nd stage, red for emergency heat and flashing red for malfunction condition in system.

4This button (on top of the cover) lights the display.

5Used to initiate or review thermostat programming or advance to next program period in programming mode.

6Used with TIME FWD /TIME BACK to set the clock.

7Used to adjust the time backward, or to select the previous menu item.

8Used to adjust the time forward, or to select the next menu item.

9Used with TIME FWD /TIME BACK to set the current day.

10Used to advance operation to the next program period or advance to the next day in programming mode.

11Used to manually override programming to hold at a selected temperature.

12Used to enter and configure the VACATION mode.

13Selects fan operation (see The Display 21 ). This button is also used to program the fan to run continuously during a program period.

14Used to set the filter change-out time, or to reset the filter change timer.

15Sets the system mode (HEATing, EMERgency (Heat Pump models only), OFF, COOLing, or AUTOmatic changeover).

16Used to adjust the clock one hour forward or back.

17Used to start or return to program operation.

2

Image 4
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Installation SpecificationsElectrical Data Thermal DataPrecautions Remove OLD Thermostat InstallationAttach Base to Wall Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusMULTI-STAGE/HEAT Pump Mode Heat Pump COMPRES- SOR ConfigurationElectric Heat FAN Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Programmable Heat FAN-OFF Delay Programmable Cool FAN-OFF and FAN-ON DelayPump Fossil Fuel KIT Alternative Economizer Feature Compressor LockoutHeating System FAN OperationUntil FAN Auto Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Programming Programmed Operation Planning Your ProgramEntering Your Program To Set the Clock To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Adjustable Temperature Display FeaturesSelectable Energy Management Recovery EMR Fahrenheit or Celsius Tem- perature Display Single Period Fan ControlHeat Fast Cool FastTraditional Features Automatic Changeover Factory Preprogrammed Times and TemperaturesActivate RUN PRG by Telephone Compressor Run Time Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonLarge Lighted Liquid Crystal Display LCD Thermostat Startup After Total Power LossArm Chair Programming Second Stage Time Delay Features IndexPage Page Part no -6422C