Emerson 1F92 manual Installer Configuration, Entering the Configuration Menus

Page 15

INSTALLER CONFIGURATION

BEFORE TURNING POWER ON, please read the following instructions. Before operating the system, you must configure the thermostat to operate properly with your equipment.

The thermostat, as it comes from the

factory, is configured to operate a standard multi-stage electric forced hot air system with a single

stage air conditioning compressor and fan. In this configuration, the thermostat will turn on the fan immediately on a call for heat. If you are unsure whether your system requires the thermostat to control the fan, contact your furnace/air conditioning system manufacturer or a qualified heating/air conditioning service person.

Your new thermostat has an Installer menu, which allows you to custom- ize the thermostat to meet your requirements.

(The thermostat also has a User menu and a Keypad Lockout menu; these menus are explained further in the CONFIGURATION section.)

The menu settings can be changed at any time to meet system or personal requirements.

ENTERING THE CONFIGURATION MENUS

After properly wiring the thermo- stat, turn on power to the system. Momentarily press PROGRAM

RUN to make certain the thermo- stat is in the run program mode,

13

then press TIME FWD and TIME BACK at the same time to enter the User Configuration menu. When the display changes to the first item in the configuration menu, release the buttons. Then press and hold SET

TIME and SET DAY for approxi- mately 3 seconds to enter the Installer menu. The display will change to show the first item on the Installer menu (multi-stage/heat pump selection). Use the following text, along with the Installer table on page 16, to guide you through the menu.

Once in the menu, you set each item to the proper selection using

or , then press TIME FWD to change the display to the next item or TIME BACK to return to the previous item.

Installation

Image 15
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Thermostat Buttons OrientationDisplay Thermal Data InstallationSpecifications Electrical DataPrecautions Installation Remove OLD ThermostatAttach Base to Wall Thermostat base and terminals Configuring ProgrammingThermostat Terminals Upper MULTI-STAGE Terminal OutputsHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower E2/P Switch Configuration Switches Reset SwitchEntering the Configuration Menus Installer ConfigurationSET Cycle HEAT, COOL, AUX Anticipation MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration Electric Heat FAN ConfigurationHeating Cooling Comments Installer TableHeat Pump 1 Programmable Cool FAN-OFF and FAN-ON Delay Programmable Heat FAN-OFF DelayPump Fossil Fuel KIT Alternative Compressor Lockout Economizer FeatureFAN Operation Heating SystemUntil FAN Auto MULTI-STAGE/HEAT Pump Auxiliary Operation Test Cooling SystemResetting Thermostat Configuration and Programming Troubleshooting Reset ButtonConfiguration User Menu Keypad Lockout Menu access from User Menu To Set the Day ProgrammingProgrammed Operation Planning Your Program Entering Your Program To Set the ClockFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Features Adjustable Temperature DisplaySelectable Energy Management Recovery EMR Cool Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Heat FastKeypad Lockout Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Activate RUN PRG by Telephone Compressor Run TimeProgrammable Fan Control Compressor Short-Cycle ProtectionSystem and Thermostat Diagnostics Air Filter Change-Out IndicatorIndefinite Program Hold Temporary Program OverrideDaylight Savings Time Button Programmable Vacation Time/ Temperature OperationThermostat Startup After Total Power Loss Large Lighted Liquid Crystal Display LCDArm Chair Programming Second Stage Time Delay Index FeaturesPage Page Part no -6422C