Emerson 1F92 Programmable Vacation Time/ Temperature Operation, Daylight Savings Time Button

Page 38

without a program running, press

PROGRAM HOLD . The or keys can be used to raise or

lower the temperature. The thermostat will hold the set temperature until you return to the program by pressing PROGRAM

RUN .

Programmable Vacation Time/ Temperature Operation.

The VACATION key allows you to program the thermostat to hold a constant temperature for 1 to 29 days. At the end of the day and time you select, the thermostat will return to normal program operation.

To program the number of days, press VACATION. VACA HOLD TILL will be displayed. The display will also show DAYS (flashing) and the number 5 to indicate the factory

default of a 5 day period. To change the number of vacation days, press

TIME FWD

or TIME BACK . Press

or

to set the tempera-

ture you wish to maintain while away. While still in the vacation mode, set the time you want the program to resume by pressing SET

TIME once. The current time will display. Press only TIME FWD to adjust the time in 15 minute increments. You may wish to select a few hours in advance of your expected return to allow time to reach the desired temperature. Your thermostat is now programmed to hold the temperature you selected through your vacation for HEAT, COOL, or AUTO.

After 20 seconds the display will return to time/temperature

alternation, and will display VACA. Pressing VACATION again will activate the vacation mode settings. Pressing PROGRAM RUN cancels this feature and begins running your normal program.

Daylight Savings Time Button.

One button adjustment allows you to change your thermostat clock between Standard Time and Daylight Savings Time. Simply push the DAYLIGHT SAVINGS TIME key to advance the time forward one hour in the Spring. In the Fall press the DAYLIGHT SAVINGS TIME key twice to fall back an hour. If you push it three times in a row (in less than 30 seconds) it will return to the original time setting. After clock adjustment,

36

Image 38
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Electrical Data InstallationSpecifications Thermal DataPrecautions Attach Base to Wall InstallationRemove OLD Thermostat Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusElectric Heat FAN Configuration MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Pump Fossil Fuel KIT Alternative Programmable Cool FAN-OFF and FAN-ON DelayProgrammable Heat FAN-OFF Delay Economizer Feature Compressor LockoutUntil FAN Auto FAN OperationHeating System Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Entering Your Program To Set the Clock ProgrammingProgrammed Operation Planning Your Program To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Selectable Energy Management Recovery EMR FeaturesAdjustable Temperature Display Heat Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Cool FastActivate RUN PRG by Telephone Compressor Run Time Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonArm Chair Programming Thermostat Startup After Total Power LossLarge Lighted Liquid Crystal Display LCD Second Stage Time Delay Features IndexPage Page Part no -6422C