Emerson 1F92 manual Programming, Programmed Operation Planning Your Program, To Set the Day

Page 28

PROGRAMMING

MANUAL OPERATION

Your Comfort-Set 90 thermostat can be used to control temperature manually (without programming). For manual operation, press SYSTEM to select HEAT or COOL, then press PROGRAM HOLD . Use or to set the tempera- ture as desired.

PROGRAMMED OPERATION Planning Your Program

The sample schedule (page 28) shows the factory installed programs for heating and cooling. The heating and cooling programs are separate, and must be programmed individu- ally. To use the factory program, set the clock and press PROGRAM

RUN with the thermostat SYSTEM set to Heat, Cool, or Auto.

Fill out the blank schedule (page 29) with the time and temperatures you want in your program. Fill in every space for your program.

The same temperature can be repeated more than once if you do not want the temperature to change over several time periods.

Entering Your Program

To Set the Clock:

1.Press PROGRAM RUN .

2.Press SET TIME . The display will show the hour. Use TIME

FWD or TIME BACK to set to the current hour and AM/PM designa- tion.

3.Press SET TIME again. The display will show minutes. Use

26

TIME FWD or TIME BACK to set to the current minutes.

4.Press PROGRAM RUN .

To Set the Day:

5.Press SET DAY . The display will indicate a day of the week. Use

TIME FWD or TIME BACK to set to the current day of the week.

6.Press PROGRAM RUN .

To Set the Program:

7.Press SYSTEM to select HEAT (for heating program) or COOL (for cooling program).

8.Press PROGRAM VIEW one time. The display will show MOR, the settings for time and temperature and MON, TUE, WED, THU, FRI.

Image 28
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Installation SpecificationsElectrical Data Thermal DataPrecautions Remove OLD Thermostat InstallationAttach Base to Wall Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusMULTI-STAGE/HEAT Pump Mode Heat Pump COMPRES- SOR ConfigurationElectric Heat FAN Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Programmable Heat FAN-OFF Delay Programmable Cool FAN-OFF and FAN-ON DelayPump Fossil Fuel KIT Alternative Economizer Feature Compressor LockoutHeating System FAN OperationUntil FAN Auto Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Programming Programmed Operation Planning Your ProgramEntering Your Program To Set the Clock To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Adjustable Temperature Display FeaturesSelectable Energy Management Recovery EMR Fahrenheit or Celsius Tem- perature Display Single Period Fan ControlHeat Fast Cool FastTraditional Features Automatic Changeover Factory Preprogrammed Times and TemperaturesActivate RUN PRG by Telephone Compressor Run Time Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonLarge Lighted Liquid Crystal Display LCD Thermostat Startup After Total Power LossArm Chair Programming Second Stage Time Delay Features IndexPage Page Part no -6422C