Emerson 1F92 manual Activate RUN PRG by Telephone Compressor Run Time, Keypad Lockout

Page 34

Activate RUN PRG by Telephone.

(User menu, Item 8) With the optional X-10 Touch Tone Control- ler and a Universal Low Voltage Module, UM506, installed, you can make a telephone call to run your program if the thermostat has been set to Hold or Vacation Hold. These optional items are available from www.x10.com, or 800-675-3044.

Compressor Run Time.

(User menu, Item 9 and 10) You can see how long the compressor has run (in hours) by viewing the User table, Item 9. You can see how long the system Auxiliary has run (in hours) by viewing the User table, Item 10. These can be reset to 00 when displayed by pressing

and at the same time.

Keypad Lockout.

(Keypad Lockout table) This security feature allows you to lock out the keypad to prevent unautho- rized tampering with the program. Two levels of security are available, Total Keypad Lockout or Partial Keypad Lockout. Total Keypad Lockout renders all buttons inoperative. Partial Keypad Lockout

allows only the or to operate for temporary temperature overrides. It also limits the tempera- ture to the maximum heating and minimum cooling temperatures used in your program. This is especially useful in buildings where unsched- uled events are common. Anyone can change the temperature, but only between the temperatures you set and only for the number of hours

you specify if you set up your Hold Till timing (see “Temporary Program Override” (page 37). To select or deselect this feature, refer to the CONFIGURATION section (page 25, Keypad Lock menu).

TRADITIONAL FEATURES Automatic Changeover.

If you have a heating/cooling system, the thermostat can be set to automatically switch the system between heating and cooling as needed. To set your thermostat to

this operating mode, press SYSTEM button until AUTO is displayed on the screen.

Factory Preprogrammed Times and Temperatures.

This thermostat has been pro- grammed at the factory. The chart in

32

Image 34
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Orientation Thermostat ButtonsDisplay Electrical Data InstallationSpecifications Thermal DataPrecautions Remove OLD Thermostat InstallationAttach Base to Wall Configuring Programming Thermostat base and terminalsMULTI-STAGE Terminal Outputs Thermostat Terminals UpperHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower Configuration Switches Reset Switch E2/P SwitchInstaller Configuration Entering the Configuration MenusElectric Heat FAN Configuration MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Installer Table CommentsHeat Pump 1 Programmable Heat FAN-OFF Delay Programmable Cool FAN-OFF and FAN-ON DelayPump Fossil Fuel KIT Alternative Economizer Feature Compressor LockoutHeating System FAN OperationUntil FAN Auto Cooling System MULTI-STAGE/HEAT Pump Auxiliary Operation TestTroubleshooting Reset Button Resetting Thermostat Configuration and ProgrammingConfiguration User Menu Keypad Lockout Menu access from User Menu Entering Your Program To Set the Clock ProgrammingProgrammed Operation Planning Your Program To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Adjustable Temperature Display FeaturesSelectable Energy Management Recovery EMR Heat Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Cool FastActivate RUN PRG by Telephone Compressor Run Time Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Keypad LockoutCompressor Short-Cycle Protection Programmable Fan ControlAir Filter Change-Out Indicator System and Thermostat DiagnosticsTemporary Program Override Indefinite Program HoldProgrammable Vacation Time/ Temperature Operation Daylight Savings Time ButtonLarge Lighted Liquid Crystal Display LCD Thermostat Startup After Total Power LossArm Chair Programming Second Stage Time Delay Features IndexPage Page Part no -6422C