Emerson 1F92 manual Temporary Program Override, Indefinite Program Hold

Page 37

thermostat will quit calling for heat for one minute (this allows some furnaces to reset) and call for heat again. It will repeat this sequence three times. If the temperature still does not rise, it will continue to call for heat. This normally indicates the heating system is not working correctly. You may wish to consult your furnace manufacturer or service person.

The display will indicate CHECK STAT if one of the following occurs.

One of the keys is stuck down or in.

Check the keys, make sure nothing is pushing them in.

The thermostat sensor is not functioning. If using a remote

sensor, check connections, wiring and power. Refer to remote sensor installation instructions

After checking the above, press PROGRAM RUN to reset the display. If this does not clear the display, disconnect power for five minutes.

If these checks fail to solve the problem, the thermostat should be replaced.

Temporary Program Override.

Any time your program is running and you would like to override it for a specific amount of time, press or until the tempera- ture you want is displayed. The display will indicate HOLD, and the number of hours remaining in the hold period will be indicated with

35

the word HRS. To adjust the length of time for the override, press TIME FWD or TIME BACK . HOLD TILL will be displayed as well as the HOLD period expiration time. Press the TIME FWD or TIME BACK keys until you reach the time you would like it to resume the program. The TIME FWD or TIME BACK keys adjust the time in 15 minute increments. This programmed hold time has a 19 hour maximum. Beyond 19 hours you may wish to use the vacation hold feature (page 36). If you need to, you can adjust the temperature up or down.

Indefinite Program Hold.

If you want to operate the thermo- stat to keep a set temperature

Features

Image 37
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Thermostat Buttons OrientationDisplay Specifications InstallationElectrical Data Thermal DataPrecautions Remove OLD Thermostat InstallationAttach Base to Wall Thermostat base and terminals Configuring ProgrammingThermostat Terminals Upper MULTI-STAGE Terminal OutputsHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower E2/P Switch Configuration Switches Reset SwitchEntering the Configuration Menus Installer ConfigurationHeat Pump COMPRES- SOR Configuration MULTI-STAGE/HEAT Pump ModeElectric Heat FAN Configuration SET Cycle HEAT, COOL, AUX AnticipationHeating Cooling Comments Installer TableHeat Pump 1 Programmable Heat FAN-OFF Delay Programmable Cool FAN-OFF and FAN-ON DelayPump Fossil Fuel KIT Alternative Compressor Lockout Economizer FeatureHeating System FAN OperationUntil FAN Auto MULTI-STAGE/HEAT Pump Auxiliary Operation Test Cooling SystemResetting Thermostat Configuration and Programming Troubleshooting Reset ButtonConfiguration User Menu Keypad Lockout Menu access from User Menu Programmed Operation Planning Your Program ProgrammingEntering Your Program To Set the Clock To Set the DayFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Adjustable Temperature Display FeaturesSelectable Energy Management Recovery EMR Single Period Fan Control Fahrenheit or Celsius Tem- perature DisplayHeat Fast Cool FastFactory Preprogrammed Times and Temperatures Traditional Features Automatic ChangeoverActivate RUN PRG by Telephone Compressor Run Time Keypad LockoutProgrammable Fan Control Compressor Short-Cycle ProtectionSystem and Thermostat Diagnostics Air Filter Change-Out IndicatorIndefinite Program Hold Temporary Program OverrideDaylight Savings Time Button Programmable Vacation Time/ Temperature OperationLarge Lighted Liquid Crystal Display LCD Thermostat Startup After Total Power LossArm Chair Programming Second Stage Time Delay Index FeaturesPage Page Part no -6422C